FS-8700-83 Gamewell Serial Driver  
APPLICABILITY & EFFECTIVITY  
Effective for all systems manufactured after May 1, 2001  
 
FS-8700-83 Gamewell  
Page 1 of 24  
1. Gamewell Serial Driver Description  
The Gamewell Serial Driver allows the FieldServer to accept messages generated by a  
Gamewell 600 Series Panel as well as ‘Smartnet Data Stream’ messages generated by a  
Gamewell Smartnet terminal.  
All Gamewell 600 Series Fire Alarm panels are equipped with a serial port, which produces  
panel, circuit or device status messages. This driver is designed to process these messages  
and store this status information in numeric form. The numeric value will indicate the type of  
event being reported and the storage location in the FieldServer’s data arrays is (configurable  
&) dependent on the origin of the message (panel / circuit / device). Additional information such  
as event date and time and descriptions are ignored.  
The driver is capable of supporting a panel configured to supervise the port by responding to the  
panel’s supervision queries.  
This is a passive client driver. The driver listens passively for unsolicited messages produced by  
the Gamewell panel. This definition is not strictly true because the driver is capable of sending  
the panel three messages: Ack, Silence and Reset.  
Design Basis: Gamewell serial port protocol specification “IF 600r7 Message Stream” (not  
dated) and “SmartNet Data stream information” (not dated).  
The driver is capable of exposing communication statistics in a FieldServer Data Array so that a  
remote device can monitor them.  
2. Driver Scope of Supply  
2.1Supplied by FieldServer Technologies for this driver  
FieldServer  
Technologies  
PART #  
DESCRIPTION  
FS-8917-16  
RS-485/RS-232 Pigtail for RJ45 port  
Driver Manual.  
2.2Provided by user  
PART #  
DESCRIPTION  
Gamewell Panel with SIM232 interface  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 2 of 24  
3. Hardware Connections  
The bridge is connected to the Gamewell panel as shown below.  
Configure the Gamewell panel according to manufacturer’s instructions  
FIELDSERVER  
RS232 PORT  
GAMEWELL  
SIM 232  
BOARD  
RJ45-01  
BROWN  
FS-8915-10  
XMT  
COM  
RCV  
GND  
COM2  
RJ45-04  
BLUE/WHITE  
RJ45-08  
ORANGE/WHITE  
(408)-262-2299  
GAMEWELL  
CONNECTION DIAGRAM  
BASE NAME:  
FILE NAME: T28700-83 .VSD  
DATE:6/4/02  
BY: MN  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 3 of 24  
4. Configuring the FieldServer as a Gamewell Serial Driver Client  
For a detailed discussion on FieldServer configuration, please refer to the FieldServer  
Configuration Manual. The information that follows describes how to expand upon the factory  
defaults provided in the configuration files included with the FieldServer (See “.csv” files on the  
driver diskette).  
This section documents and describes the parameters necessary for configuring the FieldServer  
to communicate with a Gamewell Serial Driver Server  
The configuration file tells the FieldServer about its interfaces, and the routing of data required.  
In order to enable the FieldServer for Gamewell Serial Driver communications, the driver  
independent FieldServer buffers need to be declared in the “Data Arrays” section, the  
destination device addresses need to be declared in the “Client Side Nodes” section, and the  
data required from the servers needs to be mapped in the “Client Side Map Descriptors”  
section. Details on how to do this can be found below.  
Note that in the tables, * indicates an optional parameter, with the bold legal value being the  
default.  
4.1Data Arrays  
Section Title  
Data_Arrays  
Column Title  
Data_Array_Name  
Function  
Provide name for Data Array  
Legal Values  
Up to 15 alphanumeric  
characters  
Data_Format  
Provide data format. Each data array can FLOAT, BIT, UInt16, SInt16,  
only take on one format.  
Packed_Bit, Byte,  
Packed_Byte,  
Swapped_Byte  
1-10,000  
Data_Array_Length  
Number of Data Objects. Must be larger  
than the data storage area required for  
the data being placed in this array.  
Example  
//  
Data Arrays  
//  
Data_Arrays  
Data_Array_Name, Data_Format,  
Data_Array_Length  
DA_AI_01,  
DA_AO_01,  
DA_DI_01,  
DA_DO_01,  
UInt16,  
UInt16,  
Bit,  
200  
200  
200  
200  
Bit,  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 4 of 24  
4.2Client Side Connections  
Section Title  
Connections  
Column Title  
Port  
Function  
Legal Values  
P1-P8, R1-R2  
Specify which port the device is  
connected to the Bridge  
Specify baud rate  
Baud  
2400  
The driver supports all standard  
baud rates 110 – 115200.  
Gamewell panels only support a  
baud rate of 2400.  
Parity*  
Specify parity  
None  
The driver supports the following  
options. Even, Odd, None, Mark,  
Space  
The Gamewell panels only  
support the use of no parity.  
Specify data bits  
Data_Bits*  
Stop_Bits*  
Protocol  
8
Specify stop bits  
1
Specify protocol used  
Gamewell  
Handshaking*  
Poll _Delay*  
Specify hardware handshaking  
Time between internal polls  
None  
0-32000 seconds  
default 1 second  
0
IC_Timeout  
This driver does not use an inter  
character timeout system. Failing  
to set the IC_Timeout to zero will  
result in driver errors.  
Example  
// Client Side Connections  
Connections  
Port, Baud, Parity, Protocol, Handshaking, Poll_Delay, IC_Timeout  
P8, 9600, None, Gamewell, None , 0.100s , 0  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 5 of 24  
4.3Client Side Nodes  
Section Title  
Nodes  
Column Title  
Node_Name  
Function  
Provide name for node  
Legal Values  
Up to 32 alphanumeric  
characters  
Node_ID  
Gamewell panel node address.  
0-256  
The Node Id has no meaning  
when the FieldServer is  
connected directly to Gamewell  
panel. When connecting to a  
Gamewell panel directly always  
set the Node_ID to zero. When  
connecting to a Gamewell  
SmartNet terminal. The  
Node_ID is important and  
should correspond to the  
Node_ID’s of the panel’s  
connected to the SmartNet  
terminal.  
Protocol  
Port  
Specify protocol used  
Specify which port the device is P1-P8, R1-R2  
connected to the FieldServer.  
Gamewell  
The use of R1 and R2 is only  
appropriate when a 232/485  
converter is used. The  
Gamewell panels only have a  
232 port available for  
connection.  
Example  
// Client Side Nodes  
Nodes  
Node_Name, Node_ID, Protocol, Port  
Panel1 , 0 , Gamewell, P8  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 6 of 24  
4.4Client Side Map Descriptors  
FieldServer Related Map Descriptor Parameters  
Column Title  
Function  
Legal Values  
Map_Descriptor_Name  
Name of this Map Descriptor  
Up to 32 alphanumeric  
characters  
Data_Array_Name  
Data_Array_Location  
Function  
Name of Data Array where data One of the Data Array names  
is to be stored in the Bridge  
from “Data Array” section above  
0 to maximum specified in  
“Data Array” section above  
Passive, WRBC, WRBX  
Starting location in Data Array  
Function of Client Map  
Descriptor.  
Reads (rdbc / rdb ) are not  
allowed. The use of WRBX is  
recommended for the ack /  
silence / reset functions. A  
message will be generated  
each time the value in the  
associated array is updated  
(even if the value stays the  
same.)  
Driver Related Map Descriptor Parameters  
Column Title  
Node_Name  
Function  
Name of Node to fetch data  
from  
Legal Values  
One of the node names  
specified in “Client Node  
Descriptor” above  
Any  
Data_Type  
Data type  
Alarms  
This parameter is only required  
for passive / server map  
descriptors.  
Faults  
Events  
Bus  
Comm  
The Data Type determines the  
type of data that gets stored  
when a message get received.  
The Data Type corresponds to  
the ‘Status’ field in a Gamewell  
message.  
Control  
Ack  
Signal Silence  
Troubles  
Supervisories  
Action_Numbers  
Action_Bits  
Dump  
Additional information is  
provided in section 6.2  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 7 of 24  
Length  
Length of Map Descriptor  
1 – 1000  
Controls how many elements of the data  
array are controlled by the map  
descriptor.  
Address  
Ckt  
This commonly used parameter has no  
meaning for this driver. If specified it is  
best set to zero.  
Specify the circuit number whose  
message will get stored using this map  
descriptor.  
0
Panel , 1 ,2 , 3 …. 131  
Use the keyword ‘Panel’ if the you wish  
to store data from a panel. All messages  
which do not contain the keyword ‘Ckt’ in  
the action field are deemed to be panel  
messages.  
Valid panel numbers are 1-131  
Dev  
The starting device number for the map  
descriptor. The length determines how  
many devices can have their data stored  
using this map descriptor.  
0 , 1 , 2 … 126  
Valid circuit numbers are 1-126 but this  
driver allows a device number of zero to  
allow for the storage of messages which  
don’t specify a device number.  
Ty  
Clear_On_Reset  
Store_As*  
Yes, No  
AsciiLog  
ASCII  
Only relevant when the  
Data_Type=’Dump’  
Value  
This tells the driver to store ignored  
messages in ASCII format or to dump  
them in ASCII format in the error log.  
Only relevant when the function is write.  
Gamewell_Func*  
Reset  
Ack  
This parameter tell the driver what type  
of command to send to the panel.  
Silence  
You should always Ack before you  
silence the panel.  
Timing Parameters  
Column Title  
Function  
Legal Values  
Scan_Interval  
Rate at which data is polled  
>0.1s  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 8 of 24  
Map Descriptor Example 1 – Store data from incoming messages.  
This example illustrates typical map descriptor uses to store data from panel generated messaged.  
As all these map descriptors have their Clear_On_Reset field set to yes, when a panel reset message is received all the data in the controlled  
arrays will be set to zero When a point reports its own state as normal the driver will set the appropriate element of the appropriate array to zero  
to indicate the normal state..  
Data is stored, first by finding a map descriptor with the correct circuit number. If the message doesn’t contain a circuit number then it is assumed  
to be from the panel itself. If a message contain a CKT number and no DEV number then the driver assumes the device number is zero. The  
storage location is based on the device number – it is used as an offset into the array.  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, ckt , Dev, Length, Data_Type , Clear_On_Reset  
Panel_data  
Ckt1_data01  
Ckt2_data01  
Ckt3_data01  
, DA_STATUS  
, DA_STATUS  
, DA_STATUS  
, DA_STATUS  
, 000  
, 200  
, 400  
, 600  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, Panel, 0 ,100  
, Any  
, Any  
, Any  
, Any  
, Yes  
, Yes  
, Yes  
, Yes  
, 1  
, 2  
, 3  
, 0 ,100  
, 0 ,100  
, 0 ,100  
The length determines  
the number of devices  
that can be processed  
using the map  
descriptor.  
In this example all the  
data for all these  
circuits is stored in one  
array.  
These map descriptors  
are all passive. We  
cannot poll the panel  
but we can wait  
You need one map  
descriptor for each  
circuit / panel.  
Because the Data Type  
is ‘Any’ the driver will  
set an array element  
non-zero if any  
Say a message for  
Ckt:2 Dev:20 is  
received. The driver  
looks at the device  
number and the length  
to see if the range of  
devices covers the  
incoming message. I  
this case the data  
would be stored at  
offset 20 in the map  
descriptor.  
passively for the panel  
to send us messages.  
messages indicate that  
the point in not in a  
normal condition.  
The offset is used to  
control the location in  
the array.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 9 of 24  
Map Descriptor Example 2 – Send a Reset / Ack / Silence Command.  
This example illustrates three map descriptors used to send commands to the panel. These are the only active map descriptors that can be used  
with the Gamewell Serial Driver.  
These map descriptors use the WRBX function. When the 1st element (because Data_Array_Offset = 0 ) has its value updated, even if the value  
doesn’t change, then the driver will send the command to the panel.  
Note that you are required to send an Ack before you can send a silence command. The driver does not clear the trigger by setting the array  
element back to zero. The panel does not send a message acknowledging receipt of the command, thus the driver cannot provide positive  
confirmation.  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Length, Function, Node_Name, Gamewell_Func  
Ack_md  
Sil_md  
Res_md  
, DA_ACK  
, DA_SILENCE  
, DA_RESET  
, 0  
, 0  
, 0  
, 1  
, 1  
, 1  
, wrbx  
, wrbx  
, wrbx  
, panel1  
, panel1  
, panel1  
, Ack  
, Silence  
, Reset  
Use one of these  
keywords.  
By using a wrbx you can  
have the driver send the  
command when the array  
is updated.  
Thus, to trigger any of  
these commands have the  
remote device send a  
value to the 1st element of  
the above data arrays.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 10 of 24  
5. Configuring the FieldServer as a Gamewell Serial Driver Server  
The Gamewell Serial Driver provides limited server functionality. This has been developed to allows for  
automated testing and Quality Assurance. It is not supported or documented however, at a client’s  
request it can be extended & documented (typically at an additional cost.)  
6. Advanced Topics  
6.1Driver Limitations & Exclusions  
The driver does not support scaling when data is stored in a data array. The keywords  
‘Data_Array_Low_Scale, Data_Array_High_Scale, Device_Low_Scale, Device_High_Scale’  
have no meaning for this driver. The reason for this is that the values stored by the driver have  
specific meanings based on parsing the message. Scaling is only applicable in drivers which read  
and write values from the remote device.  
6.2Data Types  
Messages contain Status and Action information. The status information indicated the state of a  
device / circuit / panel. The action information describe the event that generated the message.  
By specifying one of the following Data_Types you can filter the incoming messages so that on  
certain types of messages update certain data arrays. For example, if you are only interested in  
storing data from messages that report an alarm then set the Data_Tupe of that map descriptor to  
‘Alarms’. If you don’t care about the particular state then use the Data_Type of ‘Any’. The driver  
will set the values of the array elements non-zero if any not-normal states are reported.  
Data_Type  
Any  
Alarms  
Faults  
Events  
Bus  
Comm  
Control  
Ack  
Signal Silence  
Troubles  
Supervisories  
Action_Numbers  
Action_Bits  
Dump  
Status  
Note #  
1
2
2
2
2
2
2
2
2
2
2
3
4
5
Status:ALARM  
Status:FAULT  
Status:EVENT  
Status:BUS  
Status:COMM  
Status:CONTROL  
Status:ACK  
Status:SIG SIL  
Status:FAULT  
Status:EVENT and Action contains "Supv. Event in"  
Notes:  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 11 of 24  
1. If the Data Type is ‘Any’ then the map descriptor will be used to store data from message with  
any status.  
2. The state reported is filtered and must match the Data_Type for the associated array to be  
updated. For example, if the Data_Type of a MapDesc is ‘Alarms’ and a message is received that  
reports a Fault then the map descriptor will not be used to store the data from the message.  
3. Normally, user’s are interested in the Status of a device / circuit / panel but they may also be  
interested in the cause (or the ‘action’ in Gamewell terminology) of the message. When you  
specify the Data_Type as ‘Action Numbers’ then the driver will store a value which can be used to  
look up the action that produced the message. The most recent action number is stored over any  
older value. (The driver does not provide an event log.)  
4. Instead of storing a value to indicate the action, the driver can set a bit whose offset indicates  
the action. For example, action 30 will cause the 30th bit to be set. Action bits are stored  
retentively. This means that when a new action is reported the previous bits are left set and a new  
bit is set too.  
5. What happens if a message arrives that reports an alarm and you don’t have a map descriptor  
with a Data_Type capable of storing an alarm. You can make a catch all map descriptor and use  
the ‘Dump’ Data_Type to tell the driver to store the whole message in ASCII format in a data  
array so that you can inspect it. You can also use this map descriptor to tell the driver to dump the  
ignored message to the error log.  
6.3Status Types and Values  
Generally, the driver stores non-zero values to indicate the state of a device / circuit / panel based  
on the ‘status’ field of the incoming message. The specific non-zero value can be found in the  
following table. The value have been chosen so that they correspond to different bits.  
Status  
Alarm  
Fault  
Value Stored  
1
2
Event  
Bus  
4
8
Comm  
Control  
Ack  
Sig Sil  
Supv  
Genr  
16  
32  
64  
128  
512  
1024  
Thus if a map descriptor has its Data_Type = ‘Any’ and two messages are received , one an  
alarm and one an event, then the value of the array element will be set to 1 + 4 = 5. Thus the  
value is non-zero to report the not-normal state but inspection of the value allows you to  
determine the specific stat.  
The value’s can be changed by using the method below to add, but when you add, use the  
existing name and a new value.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 12 of 24  
When comparing these keywords to the data in the Status field of the message the driver only  
compares the first three characters. The comparison is case insensitive.  
Adding a New Status Type  
The fragment of a CSV file displayed below illustrates how to change the value associated with  
‘BUS’ to 9 and adds two new Status types, Fred and Ginger.  
Driver_Table  
Gamewell_Status_String, Gamewell_Status_Value, Protocol  
BUS  
FRED  
GINGER  
, 9  
, 100  
, 101  
, Gamewell  
, Gamewell  
, Gamewell  
There is a limitation in the use of new status types. They can only be stored using map  
descriptors with the Data_Type set to ‘Any’.  
The driver can store a maximum of 100 status types. The maximum length of the string is 9  
characters.  
6.4When do Data Arrays get cleared (Reset)  
When the Gamewell Panel is reset then the driver is able to clear the arrays. The way that the  
panel works is that when a reset is performed send the following message  
Status:NORMAL  
System Idle  
08/31/95 16:23  
After this message the panel then sends messages for all points that are not in a normal state.  
The driver uses the parameter ‘Clear_On_Reset’ to determine what gets cleared. If a map  
descriptor has this parameter set to ‘Yes’ then the arrays elements controlled by the  
Data_Array_Offset and the Length are set to zero.  
This provides a good technique of synchronizing the panel and the FieldServer. When you  
restart the FieldServer you should push the reset button on the panel so that the panel sends  
messages for all points that are not in a normal state. If you don’t do this, and some points are in  
a not-normal state then the FieldServer will not know about them until their state changes This is  
potentially dangerous.  
6.5Action Types  
Typically messages from the panel are contain not only the status of a point but also describe the  
action that caused the state to change.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 13 of 24  
Based on the table below if a message contains the string ‘Fire Alarm in’ then the action number  
will be stored as 11.  
ValueAction  
Description  
255  
Driver did not recognize action type  
System Setup  
1Skip System I/O Assignments  
2Begin System I/O Assignments  
System power up  
System programming itself  
Ignore any data from this point until "Exit Program  
Mode" is received  
See Programming Mode Entered  
3Programming Mode Entered  
4Exit Program Mode  
Control  
5Commencing System Reset  
6System Idle  
System reset button has been depressed  
System reset completed system is normal  
7System Acknowledged  
System Acknowledge button depressed  
System Signal Silence button depressed Audibles  
Silencing  
8Signals Deactivated  
System Signal Silence button depressed Audibles  
reactivating  
System automatically silenced the audible signals  
9Signals Activated  
10Signals Silenced Automatically  
Fire Alarm  
11Fire Alarm in  
Supervisory  
12Supv. Event in  
Generic  
13Genr. Event in  
Security Alarm  
14Security Alarm in  
Pre Alarm  
15Ver. Seq. in  
16Pos Al. Seq. in  
17Pre-Alarm in  
Verification sequence started  
Positive Alarm Sequence started  
Pre alarm present  
Fault  
18Alarm Tested in  
19AtoD Malfunction  
20LCD Malfunction  
22System In Walk Test  
23System Out Of Walk Test  
24System l/Os By Passed  
25All By Passed I/Os Cleared  
26I/0 Bypassed,  
Message during walk test  
System Problem  
System Problem  
Start partial or Full system walk test mode  
Finished system walk test mode  
Bypass system circuits or devices  
System not bypassed  
Starts ID of Circuit or point bypassed  
27Remote Annunciators Not RespondingSystem Problem  
28Remote Annunciators OK  
29Key Stuck in  
30Display Missing for  
31Bad Card @  
System Problem Restored  
System Problem  
System Problem  
System Problem  
System Problem  
32Card Missing @  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 14 of 24  
33New Card Detected @  
34Out of Memory Assigning  
System Problem  
System Problem  
Supervisory or trouble in circuit that automatically  
restore themselves  
35I/O Restored  
36Trouble Tested in  
37Trouble in  
System Problem  
System Problem  
38Output Shorted in  
39Dup. Dev. in  
System Problem  
System Problem  
40Dev. Missing in  
System Problem  
41Type Mismatch  
System Problem  
42Dev. Dirty in  
System Problem  
43No Response from Analog CKT  
44Open/Short in CKT  
45I/O Not Detected  
46Password Accepted  
47+5V OK On  
System Problem  
System Problem  
System Problem  
System Valid password entered  
System Problem  
48+5V Bad On  
System Problem  
49Aux. Supply OK For  
50Aux. AC Bad For  
51Aux. Batt. Bad For  
52Aux. Bad For  
System Problem  
System Problem  
System Problem  
System Problem  
53Unknown Event  
54Communication Failure  
55Communication Restored  
54Communications Failure  
55Communications Restored  
56Primary Bus Error  
57Secondary Bus Error  
58Printer fault  
System Problem  
Master lost communications with Node  
Master restored communications with Node X  
Master lost communications with Node  
Master restored communications with Node X  
Break or short in the primary class A cable  
Break or short in the secondary class A cable  
Master printer error  
59Batt. Charging OK  
60Batt. Charging  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 15 of 24  
Adding new Action Types  
The following fragment from a CSV file shows how you can add two new action types. If a  
message is received and its action field contains the text ‘FRED’ then the action number will be  
stored as 100.  
Driver_Table  
Gamewell_Action_String, Gamewell_Action_Value, Protocol  
FRED  
GINGER  
, 100  
, 101  
, Gamewell  
, Gamewell  
The driver can store a maximum of 100 action types. The maximum length of the string is 49  
characters.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 16 of 24  
6.6Advanced Map Descriptor Examples  
Example 1 : Filtering Data  
You can direct the driver to filter the incoming messages so that data arrays are only updated for particular states. For example an incoming  
messge which reports a device in Ckt 1 to be in a FAULT state (Status:FAULT) will use the map descriptor ‘Ckt1_data03’ to store the data and the  
array DA_FAULTS1 will be updated. If however, the message reported an ALARM state (Status:ALARM) then the array DA_ALRMS1 would have  
been updated.  
In fact, because the examples below provide a map descriptor where the data type is ‘Any’, each incoming message would update two data  
arrays. The DA_Status1 array would be updated by every single message and the other arrays would be updated depending on the state being  
reported in the message.  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name , Data_Array_Offset, Function, node_name, ckt  
, Length , Data_Type  
, Clear_on_Reset  
, Yes  
, Yes  
, Yes  
, Yes  
, Yes  
, Yes  
, Yes  
, Yes  
Ckt1_data01  
Ckt1_data02  
Ckt1_data03  
Ckt1_data04  
Ckt1_data05  
Ckt1_data06  
Ckt1_data07  
Ckt1_data08  
Ckt1_data09  
Ckt1_data10  
, DA_STATUS1  
, DA_AlARMS1  
, DA_FAULTS1  
, DA_EVENTS1  
, DA_BUS1  
, DA_COMM1  
, DA_CONTROL1  
, DA_ACK1  
, 000  
, 000  
, 000  
, 000  
, 000  
, 000  
, 000  
, 000  
, 000  
, 000  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, passive , panel1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 1  
, 100  
, 100  
, 100  
, 100  
, 100  
, 100  
, 100  
, 100  
, 100  
, 100  
, Any  
, Alarms  
, Faults  
, Events  
, Bus  
, Comm  
, Control  
, Ack  
, DA_SIGSIL1  
, DA_TROUBLES1  
, Signal Silence , Yes  
, Troubles , Yes  
You would need another set of these map  
descriptors for any other circuit you are  
monitoring.  
By using specific data types, the driver will  
only update the associated data arrays when  
the messages report a state that matches the  
data type.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 17 of 24  
Example 2 : Action Numbers  
You can have the driver store a value corresponding to the contents of the action field reported in the incoming messages. Actions are brief  
descriptions of the event that caused the message to be generated. A table of values vs. descriptions is provided in section 6.5. The driver stores  
the most recent action number, overwriting the previously stored action numbers. The driver does not keep an event log. The action number’s are  
set to zero, if the clear_on_reset is set to ‘yes’ and a system reset message is received.  
For example, if the string ‘Fire Alarm in’ is contained in the action field of the message the driver would store an action value of 11.  
This map descriptor can be used as well as the any of the map descriptors shown in previous examples. Thus you can have one (or more) map  
descrriptor storing the state and one storing the action number.  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name , Data_Array_Offset, Function, node_name, ckt  
Ckt1128_data12 , DA_ACTION128 , 000 , passive , panel1 , 128  
, Length , Data_Type  
, 127 , Action_Numbers , yes  
, Clear_on_Reset  
Using this data_Type the  
driver stores a value  
corresponding to the  
contents of the action field  
portion of the message sent  
by the panel. A table in  
section 6.5 provides a list  
of values vs. action  
descriptions.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 18 of 24  
Example 3 : Action Bits  
Instead of having the driver store a value to indicate the action, the driver can set a bit, whose offset indicates the underlying action. For example,  
if the string ‘Fire Alarm in’ is contained in the action field of the message the driver would set the array element at offset 11 (use table 6.5 to get  
the value vs. string) to 1.  
Important to note is that the driver does not clear a previously set bit when a new action is reported. Thus if two messages were received and the  
first reported ‘Fire Alarm in’ and the second reported ‘Supv. Event in then first the array element at offset 11 would be set to 1 and then element  
at offset 12 would be set. The element at offset 11 would remain set. Both would then remain set until a system reset is performed, the state of the  
point returns to normal (status:NORMAL) or you clear the bits by writing to the array from the remote device.  
As the driver may use up to 100 consecutive array locations for each Ckt/Device pair, if you use this method of storing data you will need one map  
descriptor for each Ckt/Device pair. In this example the map descriptor will store data for Ckt 128 device 10 only. This is indicated by the Ckt  
number being set to 128, the device number being set to 10 and the length being set to 1.  
If the driver doesn’t recognize the action type then it will set the array element at offset zero.  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name , Data_Array_Offset, Function, Node_Name, Ckt, Dev, Length , Data_Type  
Ckt1128_data12 , DA_ACTION_BITS , 000 , passive , panel1 , 128, 10 , 1 , Action_Bits  
, Clear_On_Reset  
, yes  
Only one device per map  
descriptor.  
Ensure that at 100 elements  
of data array are available  
for each map descriptor. (  
100 is the maximum action  
number.)  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 19 of 24  
Example 4 : Ignored Messages  
When messages are received that the driver cannot find a map descriptor to use to store the data from the message (say a message from a  
device on circuit 127 is received but there are no map descriptors for circuit 127) then the driver produces a MSG_IGNORED stat. You can have  
the driver dump these messages to the error log or store the message in a data array by using the DATA_Type=’Dump’. If the data is stored in a  
data array then use a data array with a ‘Byte’ format and display the array using the ruinet utility and view the array in ‘String’ format. If youhave  
the ignored messages dumped to the error log then use the RuiDebug utility to capture the error log  
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, node_name, Length , Data_Type , Clear_on_Reset, Store_As  
Store_Ignored_Msg , DA_DUMP_IGNORED, 000  
, passive , panel1  
, 1000  
, Dump  
, No  
, Ascii  
Store_As can be set to  
‘Ascii’ or ‘AsciiLog’ .  
When set to ‘Ascii’ the  
message is save to a data  
rray.  
When set to ‘AsciiLog’ the  
ignored message is dumped  
to the error log.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 20 of 24  
7. Driver Notes  
7.1IC_Timeout  
The connection IC_Timeout must be set to zero. This is done in the CSV file by setting  
IC_Timeout parameter.  
The following fragment from a CSV file illustrates how this is done.  
Connections  
Port, Baud, Parity, Data_Bits, Stop_Bits, IC_Timeout  
P1, 2400, None , 8  
, 1  
, 0  
7.2Driver Stats  
In addition to the standard FieldServer communication statistics described in the FieldServer  
User’s Manual, the Gamewell Serial Driver can also expose some driver statistics by writing data  
to a data array. A special map descriptor is required. The driver recognizes the map descriptor  
by its name which must be "Gamewell-stats" .  
The following example shows how this special map descriptor can be configured. You can copy  
this section of text directly into your CSV file.  
Nodes  
Node_name , Node_ID, Protocol  
dummy_node, 0  
, Gamewell  
Data_Arrays  
Data_Array_Name , Data_Format, Data_Array_Length  
DA_GAMEWELL_STATS, uint16 , 500  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name , Data_Array_Offset, Function, node_name ,  
Gamewell-Stats , DA_GAMEWELL_STATS, 0  
, passive , dummy_node,  
When the driver sees this map descriptor it uses the data array DA_GAMEWELL_STATS (in this  
example) to store driver specific statistics. Only one of these map descriptors may be specified  
per FieldServer.  
The offset into the array is based on the port number. 30 arrays locations are used per port.  
The offset is obtained by multiplying the port number by 30.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 21 of 24  
The driver stores the following data.  
PORT  
Description  
0
1
2
3 …  
8
Array Offset  
30 60 90  
31 61 91  
32 62 92  
33 63 93  
34 64 94  
35 65 95  
36 66 96  
37 67 97  
0
1
2
3
4
5
6
7
240 Available for future use  
241 Available for future use  
242 Available for future use  
243 Available for future use  
244 Number of bytes sent by client driver  
245 Number of messages sent by client  
246 Number of reponse messages received by client  
247 Number of response bytes received by client  
Number of times client has timeout out waiting for (response)  
248 prompt  
8
38 68 98  
Number of times client has timeout out waiting for (response)  
249 prompt  
9
39 69 99  
10 40 70 100  
11 41 71 101  
12 42 72 102  
13 43 73 103  
250 Number of Supervision Messages Sent  
251 Number of Supervision Messages Received  
252 Number of Supervision Messages Responses Sent  
253 Number of Supervision Messages Responses Received  
Number of Supervision Messages Received with a protocol  
254 error  
14 44 74 104  
15 45 75 105  
16 46 76 106  
Number of times that message containing status information  
255 was found  
Number of times that message parsing failed because an  
256 unrecognized status type was found.  
Number of time that a message containing node information  
257 was found  
Number of times that oarsing failed because 2 CR's were not  
258 found.  
17 47 77 107  
18 48 78 108  
Number of times that message parsing failed because an  
259 unrecognized status type was found.  
19 49 79 109  
20 50 80 110  
260 Number of times that parsing completed  
Number of times that the client timed out waiting for a  
261 message to be sent  
21 51 81 111  
Number of times that the client timed out waiting for a  
262 response to a supervision query  
22 52 82 112  
23 53 83 113  
24 54 84 114  
25 55 85 115  
263 Number of times that a reset command was received.  
264 Number of times that a Ack command was received.  
265 Number of times that a Silence command was received.  
Number of times that the slave received na unregonized  
266 command  
26 56 86 116  
Number of times that the slave received a command  
267 message  
27 57 87 117  
28 58 88 118  
268 Number of times that the slave received a message  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 
FS-8700-83 Gamewell  
Page 22 of 24  
8. Revision History  
Driver  
Version  
1.00  
Document  
Revision  
0
Date  
Resp  
Comment  
29May2002  
Initial Release. Issued for review, formatting.  
Connection diagrams required.  
No Changes  
13Jun2002  
19July2002  
18Sep2002  
1.00  
1.00  
1.01  
1
2
0
Releasing  
Added Status:SUPV support. Message that  
begin this way are stored as Supervisories  
(see section 6.3).  
Changes to 6.2 Reference to Supervisory  
Data Type  
Changes to 6.3 Reference to the value of a  
SUPV message.  
25Nov02  
20Aug03  
1.02  
1.02  
0
1
Changes to 6.3 Refrence to value of A GENR  
message  
Changes to 6.4 “Commencing System Reset”  
clears arrays too.  
Changes to 6.5 Variations for action types  
13/16  
Releasing  
JD  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
 

Echo Trimmer 99944200465 User Manual
Exmark Automobile Parts 000 Higher User Manual
Exmark Lawn Mower VH15KA362 User Manual
Fuji Bikes Network Card FEH381 User Manual
Fujitsu Laptop S 4572 User Manual
Furuno TV Converter Box AD 10S User Manual
GarrettCom Switch DS8016 User Manual
GE Griddle 168999 User Manual
George Foreman Fryer SKG01GFB User Manual
Global Machinery Company Power Screwdriver SG18V User Manual