UX8800
DI GI TAL SI GNAL PROCESSOR / CROSSOVER
OWNER’ S MANUAL
U-NET
1
INPUT CHAANNELS
OUTPUT CHHANNELS
CH
X-OVER
EQ
LEVEL
LIM
UX 8800Speaker / System Processor
Crossover
A
B
C
D
1
2
3
4
5
6
7
8
Clip
-6
Clip
-6
Clip
-6
Clip
-6
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
ETHERNET
Limiter
SELECT
-12
Sig
-12
Sig
-12
Sig
-12
Sig
2
PROG
UTIL
EQ
MUTE
MUTE
MUTE
MUTE
DELAY
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
1
IMPORTANT SAFETY INSTRUCTIONS - READ THIS FIRST
Read and heed all warnings and safety instructions in this Manual before using the product. Failure to
follow all precautions can result in equipment damage, personal injury, or death.
1. 1
Impor tant Safety Instructions for Electronic Products
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user of the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong is provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. The power plug at the wall must remain accessible to be able to disconnect power from the
apparatus.
11. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
12. Only use attachments/accessories specified by the manufacturer.
13. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
14. Unplug this apparatus during lightning storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
16. This apparatus shall not be exposed to dripping or splashing, and no object filled with liquid,
such as vases, shall be placed on the apparatus.
17. This apparatus has been designed with Class-I construction and must be connected to a mains
socket outlet with a protective earthing connection (the third grounding prong).
18. This apparatus does not exceed the Class A/Class B (whichever is applicable) limits for radio
noise emissions from digital apparatus as set out in the radio interference regulations of the
Canadian Department of Communications.
ATTENTION: Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant las
limites applicables aux appareils numériques de class A/de class B (selon le cas) prescrites
dans le règlement sur le brouillage radioélectrique édicté par les ministere des communications
du Canada.
Page iii
19. If the loudspeaker is exposed to changes in temperature and humidity, internal condensation
may develop. If powered up with such condensation, electronic failure could result. When
exposed to environmental changes, allow the loudspeaker at least 30 minutes to acclimate to a
new temperature before connecting to the ac mains and operating.
20. EAW loudspeakers can produce sound levels capable of causing permanent hearing damage
from prolonged exposure. The higher the sound level, the less exposure needed to cause such
damage. Avoid prolonged exposure to the high sound levels from the loudspeaker.
DANGER: There is danger of explosion if battery is incorrectly replaced. Replace only with
the same or equivalent type. This applies to any loudspeakers with a battery.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. DO NOT EXPOSE THE
APPARATUS TO DRIPPING OR SPLASHING AND DO NOT PLACE OBJECTS FILLED
WITH LIQUIDS, SUCH AS DRINKS, ON THE APPARATUS.
1
CONSIGNES DE SÉCURITÉ - À LIRE EN PREMIER
Lisez et respectez toutes les consignes de sécurité de ce manuel avat d'utiliser le produit. Le non-respect de
ces consignes de sécurité peut entraîner des dommages matériels ou des accidents aux personnes qui
peuvent être fatals.
1.1
Consignes de Sécurité Importantes Relatives aux Produits
Électronique
Le symbole del'éclair dans le triangle équilatéral prévient l'utilisateur de la présence d'une "tension
électrique dangereuse" dans le produit constituant un risque d'électrocution.
Le point d'exclamation dans le triangle équilatéral prévient l'utilisateur de la résence d'instructions
importantes relatives à l'utilisation et à la maintenance du produit dans le manuel fourni avec le produit.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respectez toutes les mises en garde.
4. Suivez toutes les intructions.
5. Ne pas utiliser cet appareil près d'une source liquide.
6. Nettoyer uniquement avec un tissu sec.
7. Ne pas obstruer les ouïes de ventilation. Installer selon les instructions du fabriquant.
8. Ne pas installer près d'une source de chaleur cmme des radiateurs, convecteurs, poêles, ou près
de tout appareil (ce qui comprend les amplificateurs de puissance) produisant de la chaleur.
9. Ne pas modifier la sécurité offerte par les fiches secteur polarisées ou avec mise à la terre. Les
fiches polaisées sont équipées de deux lames, dont une plus large que l'autre. Les fiches avec
mise à la terre disposent d'un troisième plot. La mise à la terre garantit la sécurité des
utilisateurs. Si la fiche fournie ne correspond pas au format de vos prises sectur, consultez un
électricien qui pourra les remplacer.
10. La fiche secteur dans la prise murale doit rester accessible pour permettre la déconnexion de
l'appareil du secteur.
11. Protéger le cordon secteur de toute dégradation de sorte que les personnes e puissent pas
marcher dessus. Veiller à ne pas pincer le cordon secteur, de sa sortie de l'appareil, jusqu'à la
connexion dans la prise murale ou autre.
12. Utiliser uniquement les fixations/accessoires spécifiés par le fabriquant.
13. Utiliser uniquemen le chariot, pied, tripode, fixation, ou la table spécifiés par le fabriquant, ou
vendus avec l'appareil. Lors de l'utilisation d'un chariot, vérifier la stabilité de l'ensemble
chariot/équipement pour éviter toute chute et tout accident.
Page iv
14. Déconnecter 'appareil du secteur en cas d'orage ou de périodes d'inutilisation prolongées.
15. Confier toutes les réparations à un personnel qualifié. L'appareil doit être réparé lorsqu'il a été
endommagé, lorsque le cordon ou la fiche secteur ont été endommagés, los de l'infiltration d'un
liquide ou d'un objet dans l'appareil, lorsque l'appareil a été exposé à la pluie ou à l'humidité,
s'il ne fonctionne pas correctement, ou s'il a subi une chute.
16. Cet appareil ne doit être exposé à aucune source de projection lquide. Ne pas placer d'objet
contenant un liquide sur l'appareil (verre, vase, etc.).
17. Cet appareil répond aux normes de fabrication de Classe I et doit impérativement être connecté
à une ligne secteur avec terre.
18. Cet appareil répond aux normes de lasse A/Classe B numériques du Département Canadien des
Communications (lorsque celles-ci sont applicables) sur les émissions radio générées par les
équipements.
19. Si l'enceinte est exposée à des variations de température et d'humidité, il se peut qu'un
condensation interne se produise. La mise sous tension de l'appareil en présence de cette
condensation peut entraîner une panne électrique. Si l'appareil est exposé à de telles variations,
attendez au moins 30 minutes avant de relier l'appareil au secteu et de l'utiliser.
20. Les enceintes EAW peuvent produire des niveaux sonores capables de causer des dommages
irréversibles à l'audition en présence d'une exposition prolongée. Plus le niveau sonore est
élevé, moins la durée d'exposition est longue avantde causer de tels dommages. Évitez toute
exposition prolongée aux niveaux sonores élevés.
DANGER: Danger d'explosion en cas de non remplacement correct de la pile. Remplacez
uniquement par une pile identique ou équivalente. Ceci s'applique à toutes les eceintes
équipées d'une pile.
ATTENTION: POUR RÉDUIRE LES RISQUES D'INCENDIE OU D'ÉLECTROCUTION,
NE PAS EXPOSER CET APPAREIL À LA PLUIE OU À L'HUMIDITÉ. NE PAS EXPOSER
AUX PROJECTIONS LIQUIDES ET NE PAS PLACER D'OBJET CONTENANT UN
LIQUIDE SUR L'APPAREIL (OISSON, VERRE, ETC.).
1
PRECAUZIONI DI SICUREZZA - DA LEGGERE PER PRIMO
Leggere e rispettare le avvertenze e le norme di sicurezza riportate in questo Manuale prima di uilizzare il
prodotto. Il mancato rispetto di ogni precauzione può causare danni all'apparecchiatura, nonché infortuni
alle persone o la morte.
1.1
Importanti Norme di Sicurezza per L'uso di Elettronico Prodotti
Il simbolo del lampo con la punta a freccia, racchiuso in un triangolo equilatero, avverte l'utente della
presenza di un voltaggio pericoloso non isolato all'interno del prodotto, sufficientemente alto a causare il
rischio di shock elettrico alle persone.
Ilpuntoesclamativoall'internodiuntiangoloequilatero, avvertel'utentedellapresenzadiimportantiistruzioni
operative e di mantenimento (assistenza tecnica) nella documentazione che accompagna il prodotto.
1. Leggere queste istruzioni.
2. Conservare queste istruzioni.
3. Prestare atenzione ad ogni avvertenza.
4. Seguire tutte le istruzioni.
5. Non utilizzare l'unità nelle vicinanze di acqua.
6. Pulire unicamente con un panno asciutto.
7. Non ostruire nessuna apertura adibita alla ventilazione. Effettuare l'installazione seguend le
istruzioni del costruttore.
Page v
8. L'unità dev'essere posizionata in un luogo lontano da fonti di calore come caloriferi, stufe o
altre apparecchiature che producono calore (inclusi gli amplificatori).
9. Non annullare la sicurezza garantita dall'utilizz di spine polarizzate o con messa a terra. Le
spine polarizzate sono caratterizzate dalla presenza di due lamine, una più grande dell'altra. Le
spine con messa a terra sono caratterizzate dalla presenza di due lamine e di un "dente" per la
messa a terra. a lamina maggiore e il "dente" per la messa a terra sono contemplate per
garantire la tua sicurezza. Nel caso in cui la spina del cavo incluso non si inserisca
perfettamente nella presa, si prega di contattare un elettricista per effettuarne la sostituzioe.
10. La presa di corrente alla parete dev'essere sempre facilmente accessibile, per consentire la
disconnessione dell'alimentazione dall'apparato.
11. Proteggere il cavo di corrente dall'essere calpestato o tirato, in particolare la presa e il punto in
ui il cavo esce dall'unità.
12. Utilizzare unicamente estensioni/accessori specificati dal costruttore.
13. Utilizzare esclusivamente carrelli, supporti, treppiedi, staffe, o altro specificato dal costruttore
o venduto insieme all'unità. Usando un carrell, fare attenzione a non rovesciare l'unità durante
la movimentazione.
14. Disconnettere l'unità dalla presa di corrente durante forti temporali o lunghi periodi di
inutilizzo.
15. Ogni riparazione deve essere effettuata da personale qualificato. L'assisteza è richiesta quando
l'unità risulta danneggiata in qualsiasi modo, ad esempio: cavo di corrente o presa danneggiata,
del liquido o degli oggetti sono caduti all'interno, l'unità è stata esposta all'umidità o alla
pioggia, l'unità non funziona correttamete oppure è caduta.
16. Non esporre questa unità a gocce o schizzi di alcun liquido. Non posizionare sull'unità oggetti
contenenti liquido, come vasi o bicchieri.
17. Questa unità è stata progettata in Classe-I e deve essere collegata ad una presa di corrnte con
messa a terra (spina con terzo "dente" per la messa a terra).
18. Questa unità non oltrepassa le limitazioni di Classe A/Classe B (dove applicabile) relative alle
emissioni di rumore radio generate da apparecchiature digitali, in conformità alle
egolamentazioni riguardanti le interferenze radio emesse dal Canadian Department of
Communications.
19. Se il diffusore è sottoposto a variazioni di temperatura e all'umidità, si può sviluppare della
condensa all'interno. L'attivazione dell'unità in presnza di condensa, può causare problemi al
sistema elettrico. In caso di esposizione a cambiamenti climatici, è necessario permettere al
diffusore di acclimatarsi alla nuova temperatura per almeno 30 minuti, prima di collegarlo alla
presa di corrente e inizare l'utilizzo.
20. I diffusori EAW sono in grado di generare livelli sonori che possono causare danni permanenti
all'udito in caso di esposizione prolungata. Maggiore è il livello del segnale audio, minore è il
tempo di esposizione necessario a causare ali danni. Quindi, in caso di utilizzo di livelli sonori
elevati, evitare un'esposizione prolungata.
PERICOLO: Se la batteria viene sostituita in modo non corretto, c'è il rischio di esplosione.
Effettuare la sostituzione utilizzando una batteria dello sesso tipo o equivalente. Questa norma
è valida per qualsiasi diffusore dotato di batteria.
ATTENZIONE: PER RIDURRE IL RISCHIO DI INCENDIO O SCOSSA ELETTRICA,
NON ESPORRE L'UNITÀ ALLA PIOGGIA O ALL'UMIDITÀ. NON ESPORRE QUESTA
UNITÀ A GOCCE O SCHIZZI DI ALUN LIQUIDO, E NON POSIZIONARE SULL'UNITÀ
OGGETTI CONTENENTI LIQUIDO, COME VASI O BICCHIERI.
Page vi
1
PRECAUCIONES DE SEURIDAD - LEA ESTO PRIMERO
Lea y respete todas las instrucciones de seguridad y aviso que aparezcan en este manual antes de comenzar
a usar este aparato. El no cumplir con lo indicado en esas precauciones puede dar lugar a daños en el
aparato, daños persoales o incluso la muerte.
1.1
Aviso Importante de Seguridad para Electrónico Productos
El símbolo del rayo dentro de un triángulo equilátero quiere advertir al usuario de la presencia de "voltajes
peligrosos" no aislados dentro de la carcasa de ese aparato, que pueden ser de magnitud suficiente como
para constituir un riesgo de descargas eléctricas a las personas.
El símbolo de exclamación dentro de un triángulo equilátero quiere advertir al usuario de la existencia de
instrucciones importante relativas al manejo y mantenimiento (reparaciones) en los documentos que se
adjuntan con el aparato.
1. Lea estas instrucciones.
2. Siga todas las indicaciones.
3. Cumpla con todas las precauciones.
4. Observe todas las instrucciones.
5. No utilice est aparato cerca del agua.
6. Limpie esta unidad solo con un trapo seco.
7. No bloquee ninguna de las aberturas de ventilación. Instale el aparato de acuerdo a las
instrucciones del fabricante.
8. No instale este aparato cerca de ninguna fuente de calor com radiadores, calentadores, hornos
u otros aparatos (incluyendo amplificadores) que produzcan calor.
9. No anule el sistema de seguridad que supone un enchufe polarizado o con toma de tierra. Un
enchufe polarizado tiene dos bornes de distinto tamaño; uno cn toma de tierra tiene dos bornes
iguales y una lámina para la conexión a tierra. El borne ancho o la lámina se incluyen para su
seguridad. Si el enchufe que venga con su unidad no encaja en su salida de corriente, póngase
en contacto con un electricista ara que sustituya esa salida obsoleta.
10. El enchufe de salida de corriente debe quedar accesible para que pueda desconectar el cable
del aparato en cualquier momento y sin problemas.
11. Evite que el cable de corriente pueda ser pisado o que quede aplstado, especialmente en los
conectores, receptáculos y en el punto de unión con el aparato.
12. Utilice solo accesorios/complementos especificados por el fabricante.
13. Utilice este aparato solo con un soporte, bastidor o rack especificado por el fabricate o que se
venda con el propio aparato. Cuando utilice un bastidor con ruedas, tenga cuidado al mover la
combinación soporte/aparato para evitar que pueda volcar.
14. Desconecte este aparato de la corriente eléctrica durante las tormentas o cuando no lo aya a
usar durante un periodo de tiempo largo.
15. Consulte cualquier posible reparación solamente al servicio técnico oficial. Este aparato deberá
ser revisado cuando se haya dañado de alguna forma, como en el caso de un daño en el cable
de corriente o onector, si se ha derramado algún líquido sobre la unidad, si el aparato ha
quedado expuesto a la lluvia o la humedad, si no funciona normalmente o si ha caído al suelo.
16. No permita que este aparato quede expuesto a salpicaduras de líquidos, ni coloqueobjetos que
contengan líquidos (como un florero, por ejemplo) encima de este aparato.
17. Este aparato ha sido diseñado con una construcción de clase I y debe ser conectado a una salida
de corriente que disponga de una conexión a tierra de protección (la ercera lámina que
indicamos antes).
18. Este aparato no sobrepasa los límites de la clase A/clase AB (cualquiera que sea la aplicable)
en cuanto a emisión de ruidos de radio de aparatos digitales, de acuerdo a lo que viene
estipulado en las leyes sobre inerferencias del departamento canadiense de comunicaciones.
Page vii
19. Si el altavoz queda expuesto en algún momento a cambios de temperatura o de humedad,
puede producirse condensación de agua en su interior. Si enciende la unidad mientras se
produce esa condensción, se puede producir una avería eléctrica. Por ese motivo, cuando la
unidad quede expuesta a cambios medioambientales, deje un espacio de al menos 30 minutos
para que el altavoz se aclimate a la nueva temperatura antes de conectarlo y usarlo.
20. Los ltavoces EAW son capaces de producir niveles de presión sonora capaces de producir
daños permanentes en la capacidad auditiva en caso de una exposición prolongada a los
mismos. Cuanto mayor sea el nivel de sonido, menor tendrá que ser el grado de exposicin para
producir tal tipo de daños. Evite una exposición prolongada a altos niveles de presión sonora
de este aparato.
PELIGRO: Existe el riesgo de una explosión si las pilas no son sustituidas de forma correcta.
Sustituya las pilas solo por otras igualeso de tipo equivalente. Esto se aplica a cualquier tipo
de altavoz que use una pila.
ATENCION: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGAS
ELÉCTRICAS, NO PERMITA QUE ESTE APARATO QUEDE EXPUESTO A LA LLUVIA
O A UN ELEVADO NIVEL DE HUMEDAD. NO PERMITA QE SE DERRAME NINGÚN
LÍQUIDO SOBRE ESTE APARATO, Y NO COLOQUE APARATOS QUE CONTENGAN
LÍQUIDOS ENCIMA DE LA UNIDAD.
1
SICHERHEITSHINWEISE - ZUERST LESEN
Lesen und beachten Sie alle Warnungen und Sicherheitsanweisungen dieser Bedienungsanleitung vor der
Benutzung des Produkts. Nichtbeachtung dieser Hinweise können möglicherweise zu Schäden am
Equipment oder zu Verletzungen bzw. zum Tod von Personen führen.
Sollte es Widersprüche oder Überlappungen geben mit anderen Produktanleitungen geben, so treten diese
Passagen an die entsprechenden Stelen in dieserAnleitung.
1.1
Wichtige Sicherheitsanweisungen für Elektronische Produkte
Das Blitzsymbol im gleichschenkligen Dreieck ist ein Warnzeichen für das Vorhandensein von nicht
isolierter Spannung innerhalbdes Gehäuses. Diese Spannung kann gefährlich hoch sein, so dass die Gefahr
eines elektrischen Schlages besteht.
1. Lesen Sie diese Anleitung.
2. Bewahren Sie diese Anleitung auf.
3. Beachten Sie alle Warnhinweise.
4. Befolgen Sie die Anweisungen.
5. Betreiben Sie das Gerät nicht in der Nähe von Wasser.
6. Reinigen Si das Gerät nur mit einem trockenen Lappen.
7. Verdecken Sie keine Lüftungsschlitze. Stellen Sie das Gerät nur nach den Vorgaben des
Herstellers.
8. Betreiben Sie das Gerät nicht in der Nähe von Wärmequellen wir Ölradiatoren, Heizungen,
Öfen oder anderen Htzequellen (z.B. auch Endstufen).
9. Setzen Sie keine Sicherheitsvorrichtungen wir codierte Stecker oder Schutzleiter außer Kraft.
Ein codierter Stecker hat zwei Kontaktstifte, wobei einer breiter ist als der andere Ein
Netzstecker mit Schutzleiterkontak hat zwei Kontaktstifte und zusätzlich einen dritten als
Schutzleiterkontakt. Der breitere Kontakt bzw. der Schutzleiterkontakt ist für Ihre Sicherheit
da. Wenn der Stecker nicht in Ihre Netzsteckdose passt, lassen Sie sich von einem zugelassenen
Elektrobtrieb die veraltete Steckdose austauschen.
10. Der Netzstecker an der Wand muss leicht erreichbar sein, um das Gerät vom Stromnetz trennen
zu können.
Page viii
11. Verlegen Sie das Netzkabel nicht im Durchgangsbereich und schützen Sie es vor Knicken,
besonders im Breich der Stecker oder im Bereich, wo das Kabel aus dem Gehäuse austritt.
12. Benutzen Sie ausschließlich vom Hersteller empfohlenes Zubehör.
13. Benutzen Sie ausschließlich von Hersteller empfohlene Transportvorrichtungen, Stative,
Montagebügel oder Untegestelle. Bei Benutzung einer Transportvorrichtung sollte darauf
geachtet werden, dass eine erhöhte Verletzungsgefahr durch Umkippen besteht.
14. Trennen Sie das Gerät während eines Gewitters oder eines Zeitraums längerer Nichtbenutzung
vom Stromnetz.
15 Überlassen Sie alle Servicearbeiten qualifizierten Technikern. Ein Service ist erforderlich,
wenn das Gerät einen Defekt aufweist, das Netzkabel oder der Netzstecker beschädigt ist,
Flüssigkeit in das Gehäuse eingedrungen ist, das Gerät Regen oder Feuchtgkeit ausgesetzt
wurde, das Gerät nicht einwandfrei funktioniert oder heruntergefallen ist.
16. Dieses Gerät das weder Tropfen oder Spritzer von Flüssigkeiten ausgesetzt werden noch
dürfen mit Flüssigkeit gefüllte Gefäße wie Vasen auf das Gerät gestellt wrden.
17. Dieses Gerät nach den Vorgaben der VDE Richtlinien gefertigt und benötigt daher eine
Schutzerdung über das Netzkabel bzw. die Netzsteckdose (mit drittem Schutzleiterkontakt).
18. Dieses Gerät erfüllt die Class A/Class B Richtlinien (je nachdem, elche zutrifft) in Bezug auf
die Aussendung von Störstrahlung, die von digitalen Geräten ausgehen, wie sie in den
Störstrahlungsrichtlinien der kanadischen Kommunikationsbehörde festgelegt sind.
19. Ist der Lautsprecher starken Temperatur- bzw. Feuchtigketsschwankungen ausgesetzt, kann im
Innern Kondensation auftreten. Durch die entstehende Feuchtigkeit können elektronische
Schaltungen ggf. nicht einwandfrei arbeiten. Wenn der Lautsprecher solchen
Umgebungsbedingungen ausgesetzt ist, sollten mindestens 30Minuten vergehen, bevor die
Netzspannung angeschlossen und der Betrieb aufgenommen wird.
20. EAW Lautsprecher können Schalldruckpegel produzieren, die permanente Gehörschäden nach
sich ziehen, wenn man sich diesen Pegeln zu lange aussetzt. Je höher der Pgel, desto weniger
Zeit wird benötigt, um einen Gehörschaden zu verursachen. Vermeiden daher das Hören hoher
Schalldrücke über längere Zeiträume.
VORSICHT: Von einer falsch eingesetzten Batterie geht Gefahr aus. Ersetzen Sie Batterien
nur mit dem gleiche oder gleichwertigen Typ. Diese gilt für alle Lautsprecher mit Batterien.
WARNUNG: UM FEUER ODER EINEN ELEKTRISCHEN SCHLAG ZU VERMEIDEN,
SETZEN SIE DAS GERÄT WEDER REGEN NOCH FEUCHTIGKEIT AUS. VERMEIDEN
SIE, DASS TROPFEN ODER SPRITZER AN DAS GERÄT GELANGN. STELLEN SIE
KEINE MIT FLÜSSIGKEITEN GEFÜLLTEN BEHÄLTER WIE Z.B. TRINKGLÄSER AUF
DAS GERÄT.
Page ix
1. 2
EC Declaration of Conformity
EasternAcoustic Works, as the manufacturer, hereby certifies that, in its delivered version,
Product Model:
UX8800
Product Description: Audio digital signal processor
complies with the provisions of these directives and standards:
European Council Directive on Low Voltage, 73/23/EEC
European Council Directive on Electromagnetic Compatibility 89/336/EEC and 93/68/EEC
EN 60065:2002 Audio, video, and similar electronic apparatus - safety requirements
EN 55103-1:1997 Electromagnetic compatibility. Product family standard for audio, video,
audio-visual, and entertainment lighting control apparatus for professional use - Emission
EN 55103-2:1997 Electromagnetic compatibility. Product family standard for audio, video,
audio-visual, and entertainment lighting control apparatus for professional use - Immunity
The Technical Report/File is maintained at:
LOUD Technologies Inc. Worldwide Headquarters
16220 Wood-Red Road NE
Woodinville, WA98072 USA
Tel:
Tel:
Fax:
+1 425 892 6500
866 858 5832
+1 425 487 4337
e-mail: [email protected]
Authorized Representative:
Kevin Cyrus
Director of Compliance
LOUD Technologies Inc.
Issued: April 2007
1. 3
FCC Information to the User
This equipment has been tested and found to comply with the limits for a ClassAdigital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Page x
CONTENTS
1
1.1
1
1.1
1
1.1
1
1.1
1
1.1
1.2
1.3
IMPORTANT SAFETY INSTRUCTIONS - READ THIS FIRST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Important Safety Instructions for Electronic Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
CONSIGNES DE SÉCURITÉ - À LIRE EN PREMIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
Consignes de Sécurité Importantes Relatives aux Produits Électronique . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
PRECAUZIONI DI SICUREZZA - DA LEGGERE PER PRIMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Importanti Norme di Sicurezza per L'uso di Elettronico Prodotti . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
PRECAUCIONES DE SEURIDAD - LEA ESTO PRIMERO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii
Aviso Importante de Seguridad para Electrónico Productos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii
SICHERHEITSHINWEISE - ZUERST LESEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
Wichtige Sicherheitsanweisungen für Elektronische Produkte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x
FCC Information to the User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Shipping Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Returning a Processor to EAW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
UX8800 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Networking Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
UX8800 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Physical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
AC Mains Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Audio Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
OPERATION - INITIAL SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Power On /Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
UTIL (System Set-Up) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
OPERATION - SYSTEM PROCESSOR MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Select System Processor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Signal Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
CH (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
CH (Output Channels 1 to 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
X-OVER (Output Channels 1 to 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
LIM (Output Channels 1 to 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
EQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
PROG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
DELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
OPERATION - LOUDSPEAKER PROCESSOR MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Select Loudspeaker Processor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Signal Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
CH (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
CH (Output Channels 1 to 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
LEVEL (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
X-OVER (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
EQ (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
PROG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
DELAY (Input Channels A to D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
LED INDICATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
U-Net Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Input meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Output Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
EAWPILOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Extra Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
MAINTENANCE AND SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Return and Repair Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
How To Contact EAW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
System Processor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Loudspeaker Processor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
2
2.1
2.2
2.3
3
3.1
3.2
3.3
3.4
3.5
4
4.1
4.2
4.3
4.4
5
5.1
5.2
5.3
6
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
6.11
7
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
8
8.1
8.2
8.3
8.4
9
9.1
10
10.1
10.2
10.3
10.4
11
12
12.1
12.2
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
A
B
Greybox Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
System Processor Mode Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Page 1
2
UNPACKING
2. 1
Contents
1
1 set
UX8800 Digital Processor
Internal support packaging
1
1
1
1
1
1
1
IEC Power cable 6 ft / 2 m with Nema 15-3 ac mains plug for 115V / 120 V
IEC Power cable 6 ft / 2 m with Schuko type ac mains plug for 220 V / 240 V
Ethernet crossover cable 7 ft / 2.1 m
4 A, slow-blow replacement fuse (in rear panel fuse drawer)
UX8800 Owner’s Manual (this document)
CD-ROM with EAWPilot control software and a trial version of Smaart v.6
Product registration instructions
2. 2
Shipping Damag e
If you find the processor is damaged after unpacking, save the packing materials for the carrier’s
inspection, notify the carrier immediately, and file a shipping damage claim. Although EAW will help in
any way possible, it is always the responsibility of the receiving party to file any shipping damage claim.
The carrier will help prepare and file this claim.
2. 3
Returning a Processor to EAW
If the processor must be returned, contact EAW for a Return Authorization. Use the original shipping
carton and packing materials. If the shipping carton is damaged, contact EAWfor a new carton at a nominal
charge. EAW will not be responsible for damage caused by inadequate packing.
Page 2
3
INTRODUCTION
Congratulations on purchasing the innovative UX8800 digital signal processor (DSP) from Eastern
Acoustic Works. While designed with the fundamental principles of close-coupled processing used since
the first MX Series Processors in the 1980s, the UX8800 uses EAW’s latest advances in digital technology
to provide optimum signal processing and management of EAW loudspeaker systems.
3. 1
UX8800 Description
The UX8800 is a 4-input, 8-output digital signal processor that operates in either of two modes:
System Processor: The UX8800 functions as a user-controlled, digital signal processor for
loudspeakers or for other applications requiring similar processing functions.
Loudspeaker Processor: The UX8800 functions to provide sophisticated, EAW-engineered
digital processing for specific portable and installed EAW loudspeakers.
In System Processor mode, the UX8800 provides a complete suite of state-of-the art, digital signal
processing tools, including 10 EQ filters and signal delay (up to 1200 ms) for each input and output,as well
as gain, polarity, limiting, and crossover filters.
In Loudspeaker Processor mode, one can create up to four different EAW loudspeaker processors for
specific EAWloudspeaker products or loudspeaker arrays.These are referred to as “Greyboxes.”This term
comes from certain parameters not being user adjustable (“black-boxed”), certain parameters being user
adjustable (“white-boxed,” as it were), with the combination of black/white being grey. Greybox settings
consist of preset, EAW-engineered processing parameters for the crossovers, equalization, limiting, and
other settings as an integral part of that loudspeaker’s design and operation. These settings include EAW’s
digital processing invention called Gunness Focusing™. In addition, preset limiting parameters are
designed to maximize sonic performance during active limiting while providing robust driver protection.
These preset parameters are locked down to prevent inadvertent or purposeful modifications. However, the
user retains control of gain, input EQ, signal delay, and polarity for each Greybox loudspeaker.
The simplicity of the Loudspeaker Processor mode makes the UX8800 practical for entry level users and
fast to operate for professional users. This function provides for a high level of system consistency while
retaining all necessary user alignment controls.
3. 2
Features and Benefits
•
•
•
Multiple Mode operation – Allows use as standard system processor or as dedicated
loudspeaker processor.
“Greybox” operation – Complete processing presets for EAW loudspeakers provides ease of
setup, consistency, and interoperability between EAW products and systems.
Comprehensive and intuitive front panel control – Access to operational parameters making
computer control unnecessary for simple and quick adjustments.
•
•
•
•
U-Net – EAW-designed signal and control networking between U-Net enabled products.
Digital inputs (U-Net and AES/EBU) – Reduces the total number of A/D & D/A stages.
EAWPilot software – Comprehensive software control of all hardware parameters.
Gunness Focusing capable – Implements Gunness Focusing for specific EAW loudspeaker
systems using the “Greybox” mode.
•
•
All filter parameters are compatible with EAW’s measurement and modeling software - Allows
the creation of advanced array processing.
Advanced Greybox Limiting - Provides more robust driver protection and better sonic
performance based on specific EAW driver and loudspeaker performance characteristics.
3. 3
Networking Capabilities
Standard Ethernet protocol and cabling is used to communicate with and control the processor. Both audio
and control signals can be transmitted between additional processors using the built-in U-Net network and
standard CAT-5 cabling with RJ-45 connectors. Up to 254 UX8800 processors can be linked using U-Net
so that all processors can be controlled by EAWPilot. The wiring configuration for U-Net can be a daisy-
chain (serial), a star, or a circular loop.
Page 3
3
8
9
U-NET
1
INPUT CHHANNELS
OUTPUT CHAANNELS
CH
X-OVER
EQ
LEVEL
LIM
UX 8800Speaker / System Processor
Crossover
A
B
C
D
1
2
3
4
5
6
7
8
Clip
-6
Clip
-6
Clip
-6
Clip
-6
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
ETHERNET
Limiter
SELECT
-12
Sig
-12
Sig
-12
Sig
-12
Sig
2
PROG
UTIL
EQ
MUTE
MUTE
MUTE
MUTE
DELAY
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
2
4
1
5
6
7
10
11
3. 4
Front Panel
1. Ethernet
For connection to a PC or to an Ethernet hub or switch; LEDs indicate connection status.
LEDs indicate U-Net status.
2. U-Net Indicators
3. Input Channels A to D Selects the input channel for display of or editing its parameters selected by a Function button.
4. Input Channel Meters Provides input metering after the ADC (analog to digital converter).
5. Input Channel Mutes Mutes the output signal of the corresponding input channel.
6. LCD Display
Displays parameters for function selected by the function buttons.
Joystick control for navigating menus and changing parameter settings.
Selects the function to be displayed or edited in the LCD display.
7. Encoder Knob
8. Function Buttons
9. Output Channels 1 to 8
Selects the output channel for display of or editing its parameters selected by a Function button.
Provides output metering before the DAC (digital to analog converter).
Mutes the signal and U-Net outputs of the corresponding output channel.
10. Output Channel Meters
11. Output Channel Mutes
12
13
OUTPUTS
5
INPUTS
U-NET
POWER
PUSH
PUSH
PUSH
PUSH
8
7
6
4
3
2
1
D
C
B
A
1
2
~100-240 VAC
ANALOG/AES
ANALOG
ANALOG/AES
ANALOG
50-60Hz 75W
14
15
16
17
3. 5
Rear Panel
12. IEC Receptacle
13. ac mains fuse
14. Power
ac mains input, 100 V to 240 V, 50 Hz to 60 Hz.
4 A, slow-blow (main and spare in IEC Receptacle drawer).
ac mains on and off.
15. Outputs 1 to 8
16. Inputs A to D
17. U-Net 1 and 2
XLR connectors for audio outputs (analog).
XLR connectors for audio inputs (analog for A to D or AES/EBU for A & C only).
Network ports for audio input, audio output, and control connections to additional
UX8800s and other U-Net enabled products.
Page 4
4
UX8800 INSTALLATION
4. 1
Physical Installation
CAUTION: The UX8800’s operating temperature range is 32 F to 104 F degrees / 0 C to 40
C degrees. The UX8800 may not function properly in temperatures below this range and may
be damaged in temperatures above this range.
4.1.1
MOUNTING
The UX8800 is designed to mount in a standard, 19 in equipment rack occupying one EIArack space (1.75
in). When rack mounting, use screws with mating plastic washers to help protect the finish of the UX8800.
The UX8800 weighs approximately 10 lb / 4.5 kg.
RECOMMENDED:
MAINTAIN 1-3/4 in / 45 mm CLEARANCE
ABOVE TOP AIR INTAKE GRILLES
MAINTAIN 2 in / 50 mm
CLEARANCE AROUND
FAN EXHAUST GRILLE
4.1.2
VENTILATION
An integral fan is used to properly ventilate the
UX8800. The fan is located to the rear of the left
side of the chassis. The air intake grilles are located
on the right side and on top of the chassis. Maintain
clearances around the left and right sides of the
chassis as shown in the drawing.
It is recommended to leave one empty rack space
above the UX8800 to provide 1.75 in / 45 mm
clearance above the top air intake holes for
additional ventilation.
MAINTAIN 1 in / 25 mm
CLEARANCE AROUND
SIDE AIR INTAKE GRILLES
4. 2
AC Mains Connections
VENTILATION CLEARANCES
4.2.1
AC MAINS VOLTAGE
The UX8800 has a universal, auto-ranging power supply that operates from 100Vto 240V, 50 Hz to 60 Hz.
The UX8800 is compatible with these nominal ac mains:
100 V, 110 V, 115 V, 120 V, 127 V, 220 V, 230 V, and 240 V at 50 Hz to 60 Hz.
CAUTION: To maintain compliance ratings, keep the ac mains voltage between 100 V to 240 V.
4.2.2
IEC POWER CORD RECEPTACLE
An IEC-320 ac mains inlet on the rear panel accepts the detachable power cords supplied with the unit. Use
the power cord appropriate for these nominal ac mains supply voltages.
POWER
120 V ac mains: use the power cord with the NEMA 5-15 plug, EAW part # 640-01-00
220 V ac mains: use the power cord with the Schuko plug, EAW part # 640-02-02
CAUTION: It is the user’s responsibility to provide a proper ac mains plug for any
ac mains outlet configuration that differs from those supplied with the product.
~100-240 VAC
50-60Hz 75W
4.2.3
GROUNDING
The chassis of this product is grounded through the grounding conductor of the power cord. To avoid
electric shock, plug the power cord into a properly wired and grounded receptacle before making any
connections to or operating the product.
DANGER: This equipment must be operated with the power cord grounding conductor
connected to a properly grounded ac outlet. Do not disconnect, “lift,” or otherwise remove this
ground connection. Without this connection, accessible parts, including knobs and controls
that may appear to be insulated, can render an electric shock that can cause injury or death to
operating personnel.
Page 5
4. 3
Audio Connections
4.3.1
SIGNAL CABLE
Use a good quality, 2-conductor shielded cable for all audio input and output connections.
4.3.2 INPUT CONNECTIONS
The four, female, XLR-type connectors labeledAthrough D are audio input connectors.
NOTES:
1. Select the signal type, analog or AES/EBU, in the hardware Utilities menu or
EAWPilot/UX8800 settings window.
2. XLR connector B is inactive when AES/EBU is selected for XLR connector A & B.
3. XLR connector D is inactive when AES/EBU is selected for XLR connector C & D.
Analog Pin-Out: XLR A to XLR D
Electronically balanced, line level
Pin 1: Shield
Pin 2: + (plus or high)
Pin 3: - (minus or low)
AES/EBU Pin-Out: XLR A and XLR C
Transformer isolated, balanced.
Pin 1: Signal ground (shield)
Pin 2: Channel 1
Pin 3: Channel 2
4.3.3
OUTPUT CONNECTIONS
The eight, male, XLR-type connectors labeled 1 through 8 are the audio output connectors.
Analog: XLR 1 to XLR 8
Electronically balanced, line level.
Pin 1: shield
Pin 2: + (plus or high)
Pin 3: - (minus or low)
PUSH
PUSH
B
PUSH
A
2
1
D
1 Signal Earth
(cable shield)
1 Shield
1 Shield
ALOG
ANALOG/AES
ANA
ANALOG
2 Signal 3 Signal
INPUT (digital - AES/EBU)
3-
2+
2+
3-
OUTPUT (analog) INPUT (analog)
4. 4
Network Connections
4.4.1
ETHERNET
The UX8800 communicates with a computer through its built-in, front panel, Ethernet port. This port is
configured as a standard NIC (network interface card). The UX8800 can be connected to an Ethernet
network using hub, switch, router, or wireless connections.
ETHERNET
Cable:
Mating Connector:
Wiring Configuration:
8 conductor CAT-5 or better
RJ-45 male
Standard for connection to a network hub, switch, or router
Crossover type for direct connection to a computer’s NIC
Page 6
4.4.2
U-NET
U-NET
The UX8800 can be networked with additional UX8800s and other U-Net enabled products
through its built-in U-Net ports. The rear panel U-Net 1 and U-Net 2 ports are bi-directional
communication ports used to communicate audio and/or control signals. Either or both ports may
be used to connect to other U-Net enabled products. When U-Net ports are connected, control
signals are automatically sent and received.Audio signals must be assigned to be sent and received
over U-Net channels using the CH function for the Input Channels and/or Output Channels.
1
2
Cable:
Mating Connector:
8 conductor CAT-5 cable or better
RJ-45 male
Wiring Configuration:
Standard or crossover (supplied)
NOTE: The U-Net ports auto-sense the cable wiring configuration.
CONNECTING ONE PROCESSOR TO ONE COMPUTER
CROSSOVER CABLE
(SUPPLIED)
4.4.3
PC
Ethernet
Use the processor’s front panel Ethernet port and the supplied Ethernet crossover cable to
connect directly to a computer’s 10, 10/100, or 100 Mbps Ethernet port. A user-supplied,
shorter or longer cable may be substituted. The UX8800’s Ethernet port is auto-
negotiating, meaning it will automatically exchange information over a link about speed
and duplex capabilities and negotiate these to the highest common denominator.
EAWPILOT
UX8800 "A"
U-Net
1
U-Net
2
CAUTION: An Ethernet crossover cable is required when connecting two Ethernet ports in the
same layer of the OSI model (Open Systems Interconnection Reference Model). A computer’s
Ethernet port, meaning its NIC (network interface card), and the UX8800 are both OSI layer
3 ports. Therefore, an Ethernet crossover cable is REQUIRED when directly connecting the
UX8800 to a computer’s NIC. An Ethernet crossover cable reverses transmit and receive pin
connections between the connectors at each end of the cable.
4.4.4
CONNECTING ONE COMPUTER TO MULTIPLE PROCESSORS USING U-NET
Use the front panel Ethernet port on one processor to
connect to a computer as in Section 4.5.1 above. This
PC
Ethernet
Ethernet
processor serves as a bridge to the U-Net network.
EAWPILOT
Connect other processors and this processor together
using the U-Net ports.
UX8800 "A"
UX8800 "B"
U-Net
1
U-Net
2
U-Net
1
U-Net
2
NOTE: Audio signals may also be routed between
processors over the same U-Net cables by assigning
other U-Net inputs and outputs to the input and
output channels.
Ethernet
Ethernet
UX8800 "D"
UX8800 "C"
U-Net
1
U-Net
2
U-Net
1
U-Net
2
4.4.5
CONNECTING ONE PROCESSOR TO AN ETHERNET NETWORK
Use the front panel Ethernet port and a standard Ethernet cable to connect to a 10, 10/100, or 100 Mbps
Ethernet hub or switch on the network.
PC
Ethernet
Hub or Switch
Ethernet
EAWPILOT
UX8800 "A"
U-Net
1
U-Net
2
Page 7
4.4.6
CONNECTING MULTIPLE PROCESSORS TO AN ETHERNET NETWORK
Use the front panel Ethernet port and a standard Ethernet cable to
To additional
UX8800(s)
connect each processor to a 10, 10/100, or 100 Mbps Ethernet hub,
switch, or router on a network.
PC
Ethernet
Hub or Switch
Ethernet
EAWPILOT
UX8800 "A"
U-Net
1
U-Net
2
4.4.7
CONNECTING MULTIPLE PROCESSORS TO AN ETHERNET AND U-NET NETWORK
Use the front panel Ethernet port and a standard Ethernet
Ethernet Hub or Switch
cable to connect processors to a 10, 10/100, or 100 Mbps
Ethernet hub, switch, or router on the network. Connect
additional processors to the Ethernet hub, switch, or
router or connect additional processors to the system
using the U-Net ports as in Section 4.4.4.
PC
Ethernet
Ethernet
EAWPILOT
UX8800 "A"
UX8800 "B"
U-Net
1
U-Net
2
U-Net
1
U-Net
2
NOTE: Audio signals may also be routed between
processors over the same U-Net cables by assigning
Input Channel and Output Channel signals to U-Net
channels.
Ethernet
Ethernet
UX8800 "D"
UX8800 "C"
U-Net
1
U-Net
2
U-Net
1
U-Net
2
4.4.8
SOFTWARE INSTALLATION -- EAWPILOT
EAWPilot requires an IBM compatible PC equipped as follows:
Operating System:
I/O:
Windows Vista, XP, 2000, NT, ME, or Windows 98
Ethernet network interface card (NIC) 10, 10/100, or 100 Mbps
page or contact the factory and a copy will be sent to you on a CD-ROM. Once installed and with the
computer connected to the UX8800, open EAWPilot by clicking on EAWPilot in the
Start/Programs/EAW/EAWPilot.
Page 8
5
OPERATION - INITIAL SETUP
WARNING: A digital processor provides a wide range of signal processing parameters. The
results of using incorrect or improper parameters with a loudspeaker can range from poor
sound quality to damage to the loudspeaker. Be sure any settings you make do not cause the
capabilities of the drivers in the loudspeaker system to be exceeded.
5. 1
Power On /Off
CAUTION: Before powering on the processor, make all connections to the processor and
ensure there is no audio signal present at the processor’s inputs.
Use the UX8800’s rear panel power switch to turn the ac mains supply to the processor on and off.
Always follow prudent audio system practices and procedures for powering on equipment by powering up
all equipment in the direction of the signal flow order, meaning from the input to the output of the audio
system. Power down the equipment in the reverse of this order.
5. 2
Front Panel Controls
5.2.1
DISPLAY
The LCD (liquid crystal display) screen,
along with the function buttons and joystick
provides the user interface for operating the
processor from the front panel. The display
can be adjusted for best viewing using the
UTIL/ LCD Contrast function.
CH
X-OVER
EQ
LEVEL
LIM
UX 8800Speaker / System Processor
Crossover
Limiter
EQ
SELECT
PROG
UTIL
5.2.2 FUNCTION BUTTONS
DELAY
Use the function buttons to display and edit
the operating parameters of the UX8800.
CH
EQ
Channel setup
Channel EQ
DELAY
X-OVER
LEVEL
LIM
PROG
UTIL
Channel signal delay
Crossover
Gain and polarity
Output limiting
Store and recall user programs
Global settings
NOTE: Some function buttons will have no corresponding screen depending on the mode of
operation and the channel selected. This will be indicated in the display.
5.2.3
JOYSTICK - DATA ENCODER
This is the primary control for operating the UX8800 from the front panel. The joystick has seven degrees
of motion.
UP
Push
Up
Down
Left
Right
CW
CCW
Enters and exits edit mode for the selected menu item.
Moves the display cursor up between menu items.
Moves the display cursor down between menu items.
Moves the display cursor left between menu items.
Moves the display cursor right between menu items.
Scrolls through parameter values for the selected menu item.
Scrolls through parameter values for the selected menu item.
ROTATE
COUNTER-
CLOCKWISE
ROTATE
CLOCKWISE
LEFT
PUSH
RIGHT
DOWN
Page 9
5.2.4
INPUT CHANNELS: BUTTONS A TO D
Pressing an INPUT channel button will illuminate the button and the display screen will display the
selected function’s parameters for this input. This action will also illuminate
INPUT CHAANNELS
the buttons for any output channels to which this input’s audio is routed.
A
B
C
D
5.2.5
OUTPUT CHANNELS: BUTTONS 1 TO 8
Pressing an OUTPUT button will illuminate the button and the display screen will display the selected
function’s parameters for this output.
OUTPUT CHANNELS
This action will not illuminate the
input button routing audio to this
output.
1
2
3
4
5
6
7
8
5.2.6
MUTE BUTTONS
Input Mutes:
Mutes the output signal of the corresponding Input Channel.
This does not mute the U-Net output.
Mutes signal to both the output XLR and U-Net output.
Sig
Sig
Sig
Sig
MUTE
MUTE
MUTE
MUTE
Output Mutes:
Mute settings are not saved with and therefore not recalled from Program files saved in the processor’s
memories. However, the behavior of the mutes may be changed when a program is recalled according to
the Program Load setting made in the UTILmenus.
In contrast, mute settings are saved as part of EAWPilot files (*.ept files) and are uploaded to the processor
as part of the settings stored in those files.
5. 3
The UTILfunction menu items are the global parameters for the processor. Set these parameters first.
5.3.1 DEVICE NAME
Enter a unique name for the processor, up to 16 alphanumeric characters.
5.3.2 MODE
UTIL (System Set-Up)
Select the operating mode. When changing processor modes all settings will be reset to the factory default
settings for that mode. In order to avoid losing any custom settings, save them using the PROG function
before switching modes. During the mode change, the processor reboots itself and mutes all outputs.
System Processor
Loudspeaker Processor
The processor functions as a standard digital signal processor.
The processor functions using factory set “Greybox” settings for
particular EAW loudspeaker products.
5.3.3
INPUTS A&B / INPUTS C&D
Select the signal, Analog orAES (=AES/EBU), for InputsA&B and Inputs C&D. The sample rate for the
AES signal can be 44.1 kHz, 48 kHz, 88.2 kHz, or 96 kHz. The sample-rate converter in the UX8800 will
convert the input sample rates to 48 kHz sample rate required for its internal processing.
NOTE: Input connector B is disabled when digital is selected for InputsAB and Input connector D is
disabled when digital is selected for Inputs CD.
5.3.4
TEMPERATURE
Enter the ambient temperature. This value is used to calculate the displayed delay distances. These
distances depend on the speed of sound, which depends on the temperature of the air through which the
sound passes. The temperature is adjustable in one degree increments between 32 F degrees and 104 F
degrees or 0 C degrees to 40 C degrees, depending on the Units setting. In Loudspeaker Processor mode,
the temperature is also used to calculate the air loss pre-emphasis.
Page 10
5.3.5
HUMIDITY
This is only functional in Loudspeaker Processor mode. Enter the relative humidity. This value is used to
calculate theAir Loss Pre-emphasis filters. The air loss depends on the temperature, humidity, and distance
to the listeners. The humidity is adjustable between 10% and 100% in 1% increments. Below 10%, the
absorptive properties of air have not been well quantified.
If in System Processor mode, this setting may be ignored.
5.3.6
PROGRAM LOAD OPERATION
Select the mute options for when a saved program is recalled and loaded into active memory.
Current Mutes The current input and output mute settings are used.
All Mutes
No Mutes
All inputs and outputs are muted.
All inputs and outputs are unmuted.
5.3.7
LCD CONTRAST
Adjust the LCD contrast value over the range of 0 to 100% for the best display for the viewing angle.
IMPORTANTNOTE: If the contrast is so bad that the display cannot be read, adjust the contrast by
holding the UTILbutton and turning the encoder until the display can be read.
5.3.8
Select the unit of measurement used in display of the delay distance and temperature: metric or U.S.
5.3.9 IP ADDRESS
Configure the IP(Internet Protocol) address for the front panel Ethernet port:
UNIT OF MEASUREMENT
Dynamic
Static
IP address is assigned by a network DHCP (Dynamic Host Configuration Protocol) server.
Manually enter an IP address, normally a “private” IP address. The first three number
groups in the IP address must be the same for both the computer and the UX8800. For
example: 192.168.0.N, with N being an integer from 1 to 254, unique to each device.
NOTES:
Private IP addresses are non-routable, meaning addresses that do not work over the Internet. Details
for configuring IP addresses is beyond the scope of this manual, however, this information is readily
available over the Internet.
It may be necessary to change the method EAWPilot uses to query devices and obtain their IP
addresses.
5.3.10 FRONT PANEL LOCK
Use this to lock the front panel functions, except the Mute buttons, from being operated. If you forget the
password, the processor must be reset. This will resetALLparameters to the factory default settings, erase
all programs stored in Loudspeaker Processor memories, and erase the existing password. See the
Troubleshooting Section for details.
Panel Lock Follow the prompts and enter a Pass Code for locking the front panel.
Follow the prompts and enter the previously entered Pass Code to unlock the front
panel and allow parameter adjustments and other changes.
5.3.11 ABOUT
Select to view information about the processor:
Version Number:
Device ID:
Displays the version of the firmware installed in the processor.
Displays the unique hardware ID assigned at the factory. EAWPilot uses
this device ID to identify and recognize each particular device to which it
can connect.
Page 11
6
OPERATION - SYSTEM PROCESSOR MODE
6. 1
Introduction
System Processor mode configures the processor for standard, digital signal processing functions. These
functions consist of Input Channel and Output Channel processing that includes equalization filters, signal
delay, polarity, gain, crossover filters, limiting, and high/low-pass filters. All parameters are user
accessible and user adjustable.
6. 2
Select System Processor Mode
1. Select the UTIL function.
2. Scroll down to and select: Mode
3. Select: System Processor. This will reboot the processor and reset all parameters to their default
settings for this mode.
6. 3
Signal Routing
In order to pass signal, these tasks must be completed as detailed in the sections listed.
1. Select the type of input signal connected to the XLR input connectors (5.3.3).
2. Assign one or two sources (input connector signals) to each input channel (6.4.1).
3. Assign a source (an input channel) to each output channel (6.5.1).
6. 4
Use the CH function to set the parameters for Input ChannelsAto D by selecting theAto D buttons.
6.4.1 SRC - SOURCE 1 / SOURCE 2
CH (Input Channels A to D)
Select either a single source or a sum of two sources. The same source can be selected for multiple Input
Channels. The source choices available depend on the configuration of the Input Channels as set in the
UTIL menu.
None
Analog A / AES A CH 1
Analog B / AES A CH 2
Analog C / AES B CH 1
Analog D / AES B CH 2
U-Net 1 to 32
6.4.2
Enter a name for the input channel, up to 16 alphanumeric characters.
6.4.3 U-NET OUT ASSIGN
CHANNEL NAME
Assign the summed, unprocessed sources to a U-Net output channel. This is useful for daisy-chaining a
single analog orAES source signal to multiple UX8800 units.
6. 5
Use the CH function to set the parameters for Output Channels 1 to 8 by selecting the 1 to 8 buttons.
6.5.1 SOURCE SELECT
CH (Output Channels 1 to 8)
Select one of the Input Channels as a source for the Output Channel. The same Input Channel can be the
source for multiple Output Channels.
None
Input Channel A
Input Channel B
Input Channel C
Input Channel D
Page 12
6.5.2
Assign the processed output signal to a U-Net output channel: U-Net 1 to 32
6.5.3 CHANNEL NAME
Enter a name for the output channel, up to 16 alphanumeric characters.
6. 6 LEVEL
U-NET OUT ASSIGN
Use the LEVELfunction to set Input Channel and Output Channel gain and polarity by selecting the A to
D or 1 to 8 buttons.
Level:
Polarity:
Scroll through and select the gain up to +/- 15 dB in 0.1 dB steps.
Select the polarity: + or -.
6. 7
X-OVER (Output Channels 1 to 8)
Use the X-OVER function to set crossover filters for providing an acoustic transition between a multi-
amplified loudspeaker’s subsystems. The crossover filters have the following variable parameters:
HPF / LPF
Filt:
High Pass Filter / Low Pass Filter
Set the selected HPF or LPF to be active or inactive.
Scroll through and select the crossover filter frequency from 20 Hz to 20 kHz in
1/24th Octave steps.
Freq:
Type:
Scroll through and select the crossover type and slope:
6 dB Butterworth, Bessel
12 dB Butterworth, Bessel, Linkwitz-Riley
18 dB Butterworth, Bessel
24 dB Butterworth, Bessel, Linkwitz-Riley
30 dB Butterworth, Bessel
36 dB Butterworth, Bessel, Linkwitz-Riley
42 dB Butterworth, Bessel
48 dB Butterworth, Bessel, Linkwitz-Riley
6. 8
LIM (Output Channels 1 to 8)
Use the LIM function to set the compressor / limiter parameters:
Lim:
Thrsh:
Ratio:
Sets the Comp/Lim to In (active) or Out (inactive).
Scroll through and select the limiter threshold from 20 dBu to -10 dBu in 0.1 dB steps.
Scroll through and select the compression ratio in integer increments:
1:1 to 20:1, or Inf:1.
Atk:
Scroll through and select the limiter attack from 40 µs to 1 ms in 10 µs steps, 1
ms to 40 ms in 1 ms steps. The default setting is 1 ms.
Scroll through and select the limiter release from 10 ms to 2 s in 10 ms steps.
Select the aggressiveness of the onset of limiting between a hard or soft knee.
Rel:
Knee:
6. 9
EQ
Use the EQ function to set the Input Channel and Output Channel equalization by selecting theAto D or
1 to 8 buttons. Each channel’s EQ section has 10 filters. Each EQ section has the following variable
parameters. The available parameters depend on the selected Type.
Parametric EQ: Sets the entire EQ section (filters 1 to 10) to In (active) or Out (inactive).
Type:
Scroll through and select the type for each parametric filter: Bell, 6 dB LoShelf,
12 dB LoShelf, 6 dB HiShelf, 12 dB HiShelf, 6 dB HPF, 12 dB HPF, 6 dB LPF,
or 12 dB LPF.
Scroll through and select the bandwidth for each filter: 0.02 to 10 octaves.
Scroll through and select the frequency for each filter: Variable from 20 Hz to
20 kHz in 1/24th octave steps.
BW:
Freq:
Gain:
Filt:
Scroll through and select the gain for each filter: +/- 15 dB in 0.1 dB steps.
Sets the selected filter (1 to 10) to be In (active) or Out (inactive).
Page 13
6. 10 PROG
The UX8800 has memory spaces for 50 user-savable and loadable programs for each operating mode
(Loudspeaker Processor and System Processor).
NOTE: The unit will only display programs stored in memory for the current operating mode:
System Processor or Loudspeaker Processor.
Load
Scroll through existing programs stored in the processor memories to find and
load the desired program. A program contains information for all processing
parameters except for the mute settings. Programs can only be loaded for the
specific operating mode in use.
NOTE: While mute settings are not saved, the mute preferences set in the On Prgm Load setting in
the UTILmenu will be used when loading a program.
Save
Scroll through existing programs stored in the processor’s memories and empty
memories to find a destination to save the current processing parameters. Name
the program to be saved. If a memory with an existing program is chosen,
rename the program to be saved. This will replace the existing program saved
into that memory.
Delete
Scroll through the existing programs stored in the processor’s memories and choose
one to delete. You must confirm deletion before the program can be deleted.
6. 11 DELAY
Use the DELAYfunction to set Input Channel and Output Channel signal delay by selecting theAto D or
1 to 8 buttons.
Input delay:
Output delay:
Normally used to set an overall delay for a loudspeaker or group of loudspeakers.
Normally used to time align the outputs of a loudspeaker’s individual subsystems
or as an overall delay for a loudspeaker or group of loudspeakers.
Select the signal delay up to approximately 1200 ms in one sample (20.83 µs) steps. The delay is displayed
in both milliseconds (2 decimal places) and distance (feet or meters according to the units settings).
Page 14
7
OPERATION - LOUDSPEAKER PROCESSOR MODE
IMPORTANT NOTE: In this mode only certain functions and parameters are available for user
adjustment. These will vary depending on the input configuration and the specific loudspeaker or
array selected by the user.
7. 1
Introduction
In Loudspeaker Processor mode the user can select from a list of specific EAW loudspeaker models and
arrays with factory-determined processor settings. This processing is not user accessible or adjustable.
EAW has designed the processing for each product listed and uploads it into specific, read-only memories
in the UX8800. As new loudspeaker products are released and older products are provided with Gunness
Focusing, these new settings can be uploaded into the UX8800.
The user configures one or more Input Channels by selecting a specific loudspeaker product for each. The
user then assigns the required number of outputs for each loudspeaker to that input channel as output “legs.”
In Loudspeaker Processor mode the user can also configure one or more inputs for generic signal
processing and assign it to one or more unused outputs as needed. This provides the same capabilities for
those channels as if they were in System Processor mode.
7.1.1
GREYBOX PROCESSING
When a specific loudspeaker or array is selected, there are three types of signal processing.The first two are
the processing for the Output Channels and are not user adjustable. The third type is input channel
processing that is user-adjustable.
1. Standard Processing: This consists of standard, digital processing functions, including signal
delay for driver time alignment, polarity, gain, crossover filters, and high/low-pass filters.
These settings are fixed at the factory.
2. Gunness Focusing: This consists of a precise and highly complex filter specifically designed
to correct physical and electro-acoustic anomalies inherent to the design of a loudspeaker and
which cannot be corrected using conventional digital signal processing functions. In order to
be correctable, each of these anomalies must remain constant with listener direction, signal
level, environmental differences, and loudspeaker age. These anomalies are grouped together
and treated using a single, though quite complex, Gunness Focusing filter that addresses the
entire audible frequency range. These settings are fixed at the factory.
3. Input Processing: This consists of standard digital processing functions, including signal delay
for overall delay, gain, polarity, EQ, and high/low-pass filters. These settings are user
adjustable and affect all Output Channels (legs) assigned to each input and thus the overall
performance of the loudspeaker.
7.1.2
GENERIC PROCESSING
When generic processing is selected for an Input Channel, the Input Channel and Output Channel
processing is configured for standard digital processing functions, including signal delay, gain, polarity,
EQ, limiting, and high/low-pass filters.
NOTE: When set for generic processing, the Input Channel processing can be adjusted using the
UX8800 front panel. However, Output Channel processing can only be adjusted using EAWPilot
software. It cannot be adjusted from the UX8800 front panel.
7. 2
Select Loudspeaker Processor Mode
1. Select the UTIL function.
2. Scroll down to and select: Mode
3. Select: Loudspeaker Processor. This will reboot the processor and reset all parameters to their
default settings for this mode.
Page 15
7. 3
Signal Routing
In order to pass signal, these tasks must be completed, as detailed in the sections listed.
1. Select the type of input signal connected to the XLR input connectors (5.3.3).
2. Assign one or two sources (input connector signals) to each input channel (7.4.1).
3. For each input channel, select a Greybox or Generic Processing (7.4.2).
4. Assign each Greybox or Generic Processing leg to an output channel (7.4.2.5).
7. 4
Use the CH function to set the parameters for Input ChannelsAto D by selecting theAto D buttons.
7.4.1 SRC - SOURCE 1 / SOURCE 2
CH (Input Channels A to D)
Select either a single source or a sum of two sources. The same source can be selected for multiple Input
Channels. The source choices available depend on the configuration of the Inputs as set in the UTIL menu.
None
Analog A / AES A CH 1
Analog B / AES A CH 2
Analog C / AES B CH 1
Analog D / AES B CH 2
U-Net 1 to 32
7.4.2
TYPE
Type:
Select the particular loudspeaker model to be used.
Focused means the processing uses Gunness Focusing
Legacy means the processing does not use Gunness Focusing
The current revision number for the selected file
A description of the file contents.
G.F. level:
rev:
Desc:
When the TYPE function is selected, follow this sequence of steps:
1. Scroll through the list of loudspeaker and array products and select the desired Greybox model. Select
“Generic Processing” to have that Input Channel and the Output Channel(s) to which it is assigned
function in System Processor mode with all input and output parameters fully user adjustable.
When set for generic processing, the Input Channel processing can be adjusted using the
UX8800 front panel. However, Output Channel processing can only be adjusted using
EAWPilot software. It cannot be adjusted from the UX8800 front panel.
2. Reset Input DSP: Select Yes to reset the input settings (EQ, delay, polarity, and/or gain) to their
default values or select No to retain the current settings. This setting affects the entire
loudspeaker or array. The input name and signal routing settings are not affected.
3. HPF Freq: If enabled for the selected loudspeaker model, scroll through and select the
frequency. The range will depend on the particular loudspeaker model. This setting affects the
entire loudspeaker or array. (See Section 7.7 for details.)
4. LPF Freq: If enabled for the selected loudspeaker model, scroll through and select the
frequency. The range will depend on the particular loudspeaker model. This setting affects the
entire loudspeaker or array. (See Section 7.7 for details.)
5. Out: Select the output to be used for the loudspeaker’s subsystem (referred to herein as “leg”).
6. Amp Gain: Scroll through and select the Amp Gain for the amplifier connected to that output
channel. (See Section 7.5.3 for details.)
7. Vrms: Scroll through and select the Max Voltage (maximum rms voltage) for the amplifier
connected to that output channel. (See Section 7.5.4 for details).
8. Listener Distance: Scroll through and set the Listener Distance for the array or loudspeaker to
the closest part of the audience area covered by the portion of the array to which the pre-
emphasis is applied.
9. Repeat steps 3 to 7 as applicable for the other selected loudspeaker or array legs or subsystems.
Page 16
NOTES: The Amp Gain, Max Voltage, and Listener Distance can be adjusted at any time by
selecting the CH function and the desired Output Channel then editing these parameters.
The HPF and LPF filters can be adjusted at any time by selecting the X-over function and the
desired Input Channel then editing these parameters.
7.4.3
U-NET OUTPUT
Assign the summed, unprocessed sources to a U-Net output channel. This is useful for daisy-chaining an
analog orAES source signal to multiple UX8800 units.
7.4.4
Enter a name for the input channel, up to 16 alphanumeric characters.
7. 5 CH (Output Channels 1 to 8)
Use the CH function to set the parameters for Output Channels 1 to 8 by selecting the 1 to 8 buttons.
7.5.1 SRC
Displays the Input Channel source for the selected output channel.
7.5.2 TYPE
Displays the model of the selected Greybox.
NAME
IMPORTANT !!
The Amp's Max Voltage and Amp Gain values you enter are CRITICAL in order for the
UX8800 to provide the correct acoustic balance and limiter parameters. These values
must match the actual performance of the amplifier connected to each Greybox's output.
If these values do not match the performance, the loudspeaker or array may be voiced
incorrectly, be over protected, or be under protected.
7.5.3
AMP GAIN
Scroll through and select the Amp Gain for the amplifier connected to that output channel. The range is
from 10 dB to 50 dB in 1 dB increments. This value is used by the UX8800 to determine the Output
Channel gain and limiter threshold setting.
The amplifier gain must be in dB, being 20 x log (input voltage / output voltage), the voltages being rms.
The value you enter MUST account for any gain or attenuation between the UX8800 output and the
amplifier input. Normally, the published gain specification for an amplifier is determined with its input
level control at maximum. Setting an amplifier's input level controls to less than maximum, as is often the
case to achieve good gain structure, changes the amplifier gain. In this case, the measure gain. Do not rely
on a level control's attenuation markings.
7.5.4
MAX VOLTAGE
Scroll through and select the Max Voltage (maximum rms voltage) for the amplifier connected to that
output channel. This value is used by the UX8800 to determine the limiter threshold setting.
The amplifier maximum voltage must be the rms level at clipping at the nominal impedance of the
loudspeaker, being the square root of (maximum watts at nominal Z x nominal Z). Determine this from the
amplifier specifications, calculation, or measurement.
Page 17
7.5.5
LISTENER DISTANCE AND AIR LOSS PRE-EMPHASIS
IMPORTANT !!
In order for theAir Loss Pre-emphasis to be effective, the ambient temperature and
humidity values MUST be manually entered using the UTILmenu on the UX8800's
front panel. (See Sections 5.3.4 and 5.3.5.)
If enabled, scroll through and set the Listener Distance (1 m to 256 m) from the array to the closest part of
the audience area covered by the portion of the array to which the pre-emphasis is applied.
The Listener Distance is a parameter of the Air Loss Pre-emphasis filter that compensates for high
frequency air loss over distance. The parameters of this filter are calculated from the user-entered ambient
temperature, relative humidity, and listener distance.
While only a single distance is entered for theAir Loss Pre-Emphasis Filter, the audience covered by a
given portion of an array or loudspeaker will vary in distance from the array. The
recommendation for setting the distance to the closest listeners in this area
is because there is far lower listener tolerance for excessive
brightness than a lack of brightness. Thus, if the
distance is set for the closest part of the
audience area covered by the filtered
portion of the array or loudspeaker,
then the more distant listener will
hear less bright sound. However, if
the distance is set for audience further
back in this area, then the sound for the closer
listeners in this area will be excessively bright and likely annoying. In any case, you can adjust the
brightness to taste by adjusting the distance parameter.
NOTE: To bypass theAir-Loss Pre-emphasis filter: set the Listening Dist to 1 m.
7. 6
LEVEL (Input Channels A to D)
Use the LEVELfunction to set Input Channel gain and polarity by selecting theAto D buttons.
Level:
Polarity:
Scroll through and select the gain up to +/- 15 dB in 0.1 dB steps.
Select the polarity: + or -.
7. 7
7.7.1
X-OVER (Input Channels A to D)
HPF FREQ AND LPF FREQ
X-Over HPF (if enabled): scroll through and select the frequency. The range will depend on the
particular loudspeaker model. This setting affects the entire loudspeaker.
X-Over LPF (if enabled): scroll through and select the frequency. The range will depend on the
particular loudspeaker model. This setting affects the entire loudspeaker.
The X-Over HPF and LPF filters are typically used in either of two ways.
1. Stand-alone Loudspeakers and Arrays:
For full-range loudspeakers and subwoofers, the LF subsystem has an HPF enabled that
is set to protect the loudspeaker from excessive LF signals that are below its operating
range. Normally, leave HPF settings at their default values. This is always a 12 dB per
octave Butterworth filter.
For applications such as voice-only, fill usage, and similar, set a higher frequency HPF
to restrict unwanted low frequency signals. This automatically changes the HPF filter
from its normal 12 dB per octave Butterworth filter to a more appropriate filter, most
commonly a 24 dB per octave Linkwitz-Riley filter.
For subwoofers an adjustable LPF, 24 dB per octave, Linkwitz-Riley is enabled for their
low-pass crossover filter.
Page 18
2. Loudspeakers and Arrays with Subwoofers:
To use full-range loudspeakers and arrays with subwoofers, set the X-Over LPF and HPF
filters to the desired subwoofer to full-range crossover frequencies. This automatically
changes the HPF filters from their normal settings to a more appropriate filter, most
commonly a 24 dB per octave Linkwitz-Riley filter.
While the crossover frequencies are adjustable, the type and slope of the crossover filters
are not adjustable. The reason for this is that the level of the subwoofers is rarely matched
to that of the full-range loudspeaker. For example, it is not uncommon at rock ‘n roll
shows for subwoofers to be operated at levels up to 12 dB higher than the full-range
loudspeakers. The 24 dB Linkwitz-Riley filter provides a smooth summation and
transition through the crossover region regardless of the level differences between the
full-range and subwoofer sources. Other types of filters may cause notches or peaks
through the crossover unless levels are precisely matched.
7. 8
EQ (Input Channels A to D)
Use the EQ function to set the Input Channel equalization by selecting theAto D buttons. Each channel’s
EQ section has 10 filters. Each EQ section has the following variable parameters. The available parameters
depend on the selected Type.
Parametric EQ
Type:
Sets the entire EQ section (filters 1 to 10) to In (active) or Out (inactive).
Scroll through and select the type for each filter: Bell, 6 dB LoShelf, 12 dB LoShelf,
6 dB HiShelf, 12 dB HiShelf, 6 dB HPF, 12 dB HPF, 6 dB LPF, or 12 dB LPF.
Scroll through and select the bandwidth for each filter: 0.02 to 10 octaves.
Scroll through and select the frequency for each filter: Variable from 20 Hz to
20 kHz in 1/24th octave steps.
BW:
Freq:
Gain:
Filt:
Scroll through and select the gain for each filter: +/- 15 dB in 0.1 dB steps.
Sets the selected filter (1 to 10) to In (active) or Out (inactive).
7. 9
PROG
The UX8800 has memory spaces for 50 user-savable and loadable programs for each operating mode
(Loudspeaker Processor and System Processor).
NOTE: The unit will only display programs stored in memory for the current operating mode:
System Processor or Loudspeaker Processor.
Load
Scroll through existing programs stored in the processor memories to find and
load the desired program. A program contains information for all processing
parameters except for the mute settings. Programs can only be loaded for the
specific operating mode in use.
NOTE: While mute settings are not saved, the mute preferences set in the On Prgm Load setting in
the UTILmenu will be used when loading a program.
Save
Scroll through existing programs stored in the processor’s memories and empty
memories to find a destination to save the current processing parameters. Name
the program to be saved. If a memory with an existing program is chosen,
rename the program to be saved. This will replace the existing program saved
into that memory.
Delete
Scroll through the existing programs stored in the processor’s memories and choose
one to delete. You must confirm deletion before the program can be deleted.
7. 10 DELAY (Input Channels A to D)
Use the DELAYfunction to set Input Channel signal delay by selecting theAto D buttons. The input delay
is normally used to set an overall delay for a loudspeaker or group of loudspeakers.
Select the signal delay up to approximately 1200 ms in one sample (20.83 µs) steps. The delay is displayed
in both milliseconds (2 decimal places) and distance (feet or meters according to the units settings).
Page 19
8
LED INDICATORS
8. 1
Ethernet
The LEDs on the Ethernet connector indicate the Ethernet connection and activity status.
ETHERNET
Left Link LED
Amber color
Green color
On
Status
Right Activity LED Status
10 Mbps
Amber color
Green color
On/flashing
Off
Half duplex
100 Mbps
Link established
No link
Full duplex
Data activity
No activity
Off
U-NET
1
8. 2
U-Net Indicators
2
The U-Net LEDs on the front/rear panels indicate the U-Net network status.
Green LED (ꢀ) Red/Yellow LEDs (!) Status
On
On
Off
U-Net network detected
U-NET
Flashing
Local fault: not sending or receiving on the assigned
U-Net channel(s) or local and received sample rates are
not synchronized
1
2
On
Off
On (2 seconds)
Off
Local fault detected on another device on the network
No network detected
8. 3
Input meters
The input meters indicate the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of theADC
(analog to digital converter). An input meter still functions when its Input Channel is muted. Ideally, the
highest levels of the signal should illuminate the -6 LED segment, but not the CLIP segment. Occasional
flashing of the CLIPsegment may be sonically acceptable.
LED Segment
Clip Red
- 6 Yellow
-12 Green
Sig Green
Signal Level
0 dBFS
INPUT CHAANNELS
A
B
C
D
-6 dBFS
Clip
-6
Clip
-6
Clip
-6
Clip
-6
-12 dBFS
-40 dBFS
-12
Sig
-12
Sig
-12
Sig
-12
Sig
8. 4
Unlike the input meters, the four LED segments of each output meter make up two different meters.
8.4.1 SIG, -12, AND CLIP SIG SEGMENTS
Output Meters
These three segments monitor the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of the
DAC (digital to analog converter). An output meter still functions when its Output Channel is muted.
Ideally, you want the highest level to illuminate the -12 segment, but not the CLIP segment. You can set
levels lower than this, but understand that you are reducing the signal-to-noise ratio.
OUTPUT CHHANNELS
LED Segment Signal Level
2
3
4
5
6
Clip Red
0 dBFS
-12 dBFS
-40 dBFS
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
Clip
Lim
-12
Sig
-12 Green
Sig Green
8.4.2
LIM SEGMENT
This segment monitors the limiter status referenced to the level set for the limiter threshold. The Lim
segment will indicate limiting even when its Output Channel is muted.
LED Segment
Lim Yellow
Status
On when the limiter threshold is exceeded and there is gain reduction
Occasional flashing is OK. However, if the LED is rapidly flashing yellow or is on steadily a large
percentage of the time, the input signal to the loudspeaker may be exceeding the loudspeaker’s capability
and the volume level should be reduced.
Page 20
9
EAWPILOT
9. 1
Extra Capabilities
While the UX8800 interface window in EAWPilot software provides the same capabilities for controlling
the UX8800 as its front panel controls, it also provides additional capabilities not available using the front
panel controls.
9.1.1
LEVEL MONITORING - ANY MODE
The meters in EAWPilot provide more accurate and much higher resolution signal level monitoring.
Both the average and peak levels are easier to read and provide mush better tracking for critical
situations.
9.1.2
PARAMETER LINKING - EITHER MODE
Using the Map tab in the UX8800 interface window, parameter values for the input channels and
the output channels may be linked so that any changes will affect all such linked parameters.
9.1.3
FIRMWARE UPDATE - EITHER MODE
Using the Settings tab in the UX8800 interface window, the firmware program for the UX8800 can
be updated.
9.1.4
RESPONSE GRAPHS - SYSTEM PROCESSOR MODE
The Input Channel and Output Channel tabs provide a frequency response graph showing filter
responses and gain for the selected channel. As well, the Xover tab provides the responses of the
crossover filters.
9.1.5
RESPONSE GRAPHS - LOUDSPEAKER PROCESSOR MODE
The Input Channel tabs provide a frequency response graph showing user-adjustable filter
responses and gain for the selected channel.
9.1.6
OUTPUT PROCESSING - LOUDSPEAKER PROCESSOR MODE
When an input channel is set for generic processing in this mode, the processing parameters for any
output channels to which it is assigned can be adjusted using EAWPilot.
Page 21
10
MAINTENANCE AND SERVICE
10. 1 Maintenance
The only routine and periodic maintenance for the processor is physical cleaning and performance testing.
10.1.1 CLEANING
Clean the exterior surfaces of the chassis as required, using a soft, dry cloth to remove any dust or dirt.
Remove any dirt from the air intake holes on the side and top of the chassis. Remove any dirt accumulated
on the ventilation fan grille.
CAUTION: To avoid damaging the exterior finishes or internal circuitry do not use any liquid,
cleaning solvents, or abrasives.
While the interval between cleanings will depend on the frequency of usage and the conditions of use, it is
recommended that cleaning be performed at least once a year. Clean more often if used in dusty or dirty
conditions, such as part of a portable or touring system.
10.1.2 PERFORMANCE TESTING
Perform listening tests and/or formal measurements, checking all processor functions for proper operation.
While the interval between testing will depend on the frequency of usage and the conditions of use, it is
recommended that should be performed at least once every six months. Test more often if used in
conditions that subject the unit to mechanical stress, such as part of a portable or touring system.
10. 2 Ser vice
There are no user serviceable parts inside the UX8800 processor. In case of failure, refer all servicing to the
factory. Service and repair information may be obtained by contacting the EAWService Department or the
EAW distributor for your country.
10. 3 Return and Repair Issues
UX8800 repairs can be done either through an EAW distributor, EAW authorized service center, or by
shipping the product to EAW Service. Prior to returning any product to EAW, an RA (Return
Authorization) issued by EAW is required. Contact the EAW Service Department for details.
10. 4 How To Contact EAW
We have tried to answer most questions you may have about the UX8800 in this manual. Should you need
further assistance, please do not hesitate to contact us. You can contact EAW in several different ways:
General and Application Support Group
EasternAcoustic Works
One Main Street
Tel
Tel
Fax
Fax
800 992 5013
+1 508 234 6158
+1 508 234 8251
800 322 8251
Whitinsville, MA 01588 USA
Web Site
Service
EAW Service Department
Building #11
Tel
Tel
Fax
800 992 5013
+1 508 234 6158
+1 508 234 3776
One Main Street
Whitinsville, MA01588 USA
e-mail
General information
Applications Support Group
Service
Page 22
11
TROUBLESHOOTING
Troubleshooting a malfunctioning UX8800 consists primarily of determining if it is incorrect settings,
faulty or incorrect connections, or an electronic failure requiring service. This table lists some possible
trouble symptoms, causes, and corrective actions.
Symptom
Probable Cause
Corrective Action
No power light
Power cord disconnected
Ensure the power cord is properly connected at both ends and that the ac mains is working.
No power light
Rear panel power switch is off Turn the power switch on.
No power light
No power light
Improper ac mains voltage The UX8800 is deigned for an ac mains voltage between 100 V and 240 V, 50 Hz to 60 Hz. If outside
these ranges, the UX8800 may fail to operate or become damaged.
ac mains fuse is blown due to an Disconnect the ac mains from the unit. Using a small screwdriver gently pry out the small drawer
that is part of the rear panel ac mains connector.Check the fuse located on the right hand side. If the
fuse is blown but glass remains essentially clear, this can indicate a faulty fuse or temporary external
event, such as an excessive ac mains voltage spike. Replace the fuse with the supplied spare
replacement fuse located on the left side of the drawer. If the fuse blows again, it indicates an
internal failure and the UX8800 should be repaired by qualified service personnel.
Replacement Fuse: 4 A, slow-blow, 5 mm x 20 mm, 250V IEC
external cause
No power light
ac mains fuse is blown due to an Disconnect the ac mains from the unit. Using a small screwdriver gently pry out the small
drawer that is part of the rear panel ac mains connector.Check the fuse located on the right hand
side. If the fuse is blown and the glass is heavily blackened, this usually indicates an internal
failure. Do not replace the fuse. The UX8800 should be repaired by qualified service personnel.
internal failure
No input meter lights
Incorrect settings
Check to be sure that:
1. The correct input signal type has been selected in the UTIL menu for Inputs A&B and Inputs
C&D.
2. Signal sources have been assigned in the CH menu for Channels A to D.
No input meter lights
No input meter lights
No input meter lights
No signal
Check to be sure there is signal from the source feeding the UX8800.
Cables disconnected or faulty Check the input cables to the UX8800 for faults or mis-wiring.
Internal failure
Internal failure is possible. The UX8800 should be repaired by qualified service personnel.
No input and/or output meter
lights
Check to be sure that all signal processing functions, especially gain controls, are correctly set
for the intended application and that input and output channel source source assignments are
correct.
Incorrect settings
No input and/or output meter
lights
Internal failure
Internal failure is possible. The UX8800 should be repaired by qualified service personnel.
No output but meter lights work Mutes are engaged
If the the output meters are functioning and there is no output, check to be sure that the output
mutes are not activated. The meters function independently of the mute switch.
No output and no output meter Incorrect configuration
lights on some or all channels
Check that the output(s) is assigned an Input Channel Signal Source.
No output and no output meter Incorrect settings
lights on some or all channels
Check to be sure that all signal processing functions, especially gain controls, are correctly set
for the intended application.
Strange malfunction(s), LCD
display corrupt, or any of the
above symptoms in this chart.
Digital lock-up
Power off, wait 10 seconds, then power on the processor to reset the digital electronics.
Panel is locked and forgot Pass
Code
Reset the processor, contacting the factory for details on how to do this. WARNING: This
process will reset ALL parameters to the factory default settings, erase all programs stored in
Loudspeaker Processor memories, and erase the existing Pass Code.
Alzheimers or equivalent
Ethernet and/or U-Net connection Network connection faulty
does not work
Check the network LED indicators to determine the connection status. For indicator details, see
Chapter 8. This may help to determine the corrective action needed.
Ethernet connection does not
work
Incorrect cable
For direct connection to a computer, you must use the supplied Ethernet crossover cable or or
an equivalent user-supplied cable. For a connection to an Ethernet hub, switch, or router, you
must use a user-suppled, standard Ethernet cable.
Ethernet connection does not
work
IP address is incorrect
IP address is incorrect
For a direct connection to a computer, set the IP address in the UTIL menu to static. Manually
assign the IP address by determining the computer’s IP address, making the first three number
groups the same as the computer’s, and making the fourth number group unique to the UX8800.
Ethernet connection does not
work
For a connection to an Ethernet network, set the IP address in the UTIL menu to dynamic.
Power off and then power on the UX8800. If a DHCP server is present, it should assign an IP
address to the UX8800. If it fails to find an address, set the IP address to static and manually
assign it an IP address, making the first three number groups the same as the other devices on
the network and making the fourth number group unique to the UX8800.
U-Net connection does not work Cable problem
for EAWPilot control
Check that the cabling is a standard or crossover CAT-5 Ethernet cable and that the cable is
functioning correctly. The U-Net ports auto-sense the cable configuration. The supplied Ethernet
crossover cable can be used for interconnecting U-Net ports. Note: Control signals are
automatically sent and received over U-Net connections.
U-Net connection does not work Audio signal(s) not assigned to Sending and receiving audio over U-Net requires assigning Input Channel and Output Channels
for audio
the U-Net channels
to the desired U-Net channels. In other words, there must be signals assigned to be sent over a
U-Net channel in order to receive signals on that U-Net channel. Use the CH U-Net Output
function for the Input Channels and Output Channels to send signals to U-Net channels. Use the
CH Src function for the Input Channels to receive U-Net signals from U-Net Channels.
Page 23
12
BLOCK DIAGRAMS
12. 1 System Processor Mode
Page 24
12. 2 Loudspeaker Processor Mode
Page 25
APPENDIX
A
Greybox Information
PURPOSE FOR GREYBOX FILES
In Loudspeaker Processor mode, the UX8800 allows loading files with factory-determined processing for
specific loudspeaker models and arrays. This processing includes equalization, crossovers, high and/or
low pass filtering, signal delay, and level control. In addition, files with Gunness Focusing also include
proprietary processing invented by EAW specifically for correction of inherent loudspeaker anomalies.
Often, audio system designers, technicians, or end-users attempt to create loudspeaker processing from
scratch using one of the several, excellent measurement systems publicly available. However, the systems
and methods cannot duplicate what is involved for EAW engineers to create Greybox processor settings:
•
•
•
•
Loudspeaker data far greater in quantity, types, precision, and accuracy (especially polar data).
Use of proprietary analysis tools developed specifically for loudspeaker data.
Use of proprietary Gunness Focusing algorithms for the processing.
Extensive listening tests performed by a wider range of people over a much greater time period
and under a much greater range of conditions.
•
•
Controlled, laboratory conditions.
Extensive knowledge in the application of loudspeaker data analysis and signal processing.
B
System Processor Mode Processing
In System Processor mode, the UX8800 may appear similar to other digital signal processors. However, the
processing algorithms used in the UX8800 differ from the normal, “textbook” algorithms used in digital
processors. EAW developed new algorithms specifically tailored for digital audio processor hardware.
FILTER RESPONSE EXAMPLE
The accuracy and precision of the UX8800 filter responses can be compared to those using textbook
algorithms. When applied to audio processing hardware, the latter do not provide textbook responses. The
two graphs compare the results of EAW’s processing algorithms and standard “textbook” algorithms as
used in well-accepted, digital signal processors. The frequency responses and phase response are for the
UX8800 (lower curves) and a non-EAW processor (upper curves). The settings were two filters set for a 5
dB boost, 1 octave bandwidth (Q = 1), at frequencies of 1 kHz and 15 kHz. There are several things to note:
1. The upper curve is the upper curve becasuse its filter skirts extend somewhat beyond that of
an ideal filter. In this case, the lower -3 dB point for the 1 kHz filter is actually over an octave
below the filter frequency. The EAW response follows the response of an ideal filter.
2. The shapes of both the 1 kHz and 15 kHz filter frequency and phase responses are different for
the non-EAW processor. In contrast, the frequency and phase response shapes of the two EAW
filters are quite similar. When overlayed, they prove to be virtually identical.
3. Because of the difference in two non-EAW filter shapes, the response of the filters overlaps too
much, resulting in an excessive boost in the 5 kHz to 10 kHz region.
Frequency Responses
Phase Responses
Page 26
Page 27
Page 28
Page 29
One Main Street, Whitinsville, MA USA 01588 508-342-6158 FAX 508-234-8251
Part No. 0018676-00 (A00) June 2007
© Loud Technologies Inc. 2007
|